Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Top Cited Papers
- 21 March 2016
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 28 (6) , 1242-1249
Abstract
Despite the many ergonomic advantages of eccrine perspiration (sweat) compared to other possible biofluids (particularly in “wearable” devices), sweat remains an underrepresented source of biomarker analytes compared to the established biofluids blood, urine, and saliva. Upon closer comparison to other non‐invasive biofluids, the advantages may even extend beyond ergonomics: sweat might provide superior analyte information. A number of challenges, however, have historically kept sweat from its place in the pantheon of clinical samples. These challenges include very low sample volumes (nL to µL), unknown concentration due to evaporation, filtration and dilution of large analytes, mixing of old and new sweat, and the potential for contamination from the skin surface. More recently, rapid progress in “wearable” sweat sampling and sensing devices has resolved several of the historical challenges. However, this recent progress has also been limited to high concentration analytes (µM to mM) sampled at high sweat rates (>1 nL/min/gland, e.g. athletics). Progress will be much more challenging as sweat biosensing moves towards use with sedentary users (low sweat rates or not sweating at all) and/or towards low concentration analytes (pM to nM). Addressing these unresolved challenges will require significant advances in sweat stimulation, sample collection efficiency, compact sensors, and likely more. Fortunately, none of the remaining challenges appear to be fundamentally blocking, and scientific and engineering innovations have the opportunity to enable broader application of sweat biosensing technology.Keywords
Funding Information
- Univ. of Cincinnati provided by the National Science Foundation (1347725)
- Air Force Research Labs 711th Human Performance Wing
- USAF (FA8650-15-C-6625)
- Center for Advanced Design and Manufacturing of Integrated Microfluidics (IIP-1362165)
- Univ. of Cincinnati College of Pharmacy
This publication has 18 references indexed in Scilit:
- Artificial microfluidic skin for in vitro perspiration simulation and testingLab on a Chip, 2013
- MIP-based biomimetic sensor for the electronic detection of serotonin in human blood plasmaSensors and Actuators B: Chemical, 2012
- On-line sample pre-concentration in microfluidic devices: A reviewAnalytica Chimica Acta, 2012
- Proteomic Analysis of Eccrine Sweat: Implications for the Discovery of Schizophrenia Biomarker ProteinsJournal of Proteome Research, 2012
- Tribology of Skin: Review and Analysis of Experimental Results for the Friction Coefficient of Human SkinTribology Letters, 2011
- Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid ArchitecturesAccounts of Chemical Research, 2010
- Monitoring Pregnant Women's Illicit Opiate and Cocaine Use With Sweat TestingTherapeutic Drug Monitoring, 2010
- A wearable electrochemical sensor for the real-time measurement of sweat sodium concentrationAnalytical Methods, 2010
- Nanoduct® sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosisEuropean Journal of Pediatrics, 2007
- The measurement of hormones in saliva: Possibilities and pitfallsJournal of Steroid Biochemistry, 1987