Validation of whole blood impedance aggregometry as a new diagnostic tool for HIT
Authors:
- Ross BakerRBRoss Baker
- Peter MolleePMPeter Mollee
- Marie-Christine Morel-KoppMMMarie-Christine Morel-Kopp
- the ASTH Clinical Trials GroupTGthe ASTH Clinical Trials Group
- 1 January 2012
- journal article
- research article
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 107 (03) , 575-583
Abstract
Heparin-induced thrombocytopenia (HIT) remains a challenge, with diagnosis confirmed only by functional assays. The gold standard 14C-se-rotonin release assay (SRA) is highly sensitive but technically challenging and unsuitable for routine use. We conducted a large study to validate whole blood impedance aggregometry (WBIA) as a suitable diagnostic tool for HIT. WBIA and SRA were used to test 181 samples positive for H-PF4 antibodies by PaGIA or ELISA. Using the same high responder donor, 77 samples were positive by WBIA (aggregation with low-dose but not high-dose heparin). Using the strict definition for SRA positivity, 72 samples were true HIT. In nine samples, serotonin release with high-dose heparin dropped by > 50% but was still >20%; these were retested after a one-half dilution and 8/9 became positive. Ten other samples were discrepant between the two assays: one strongly positive (89% release) and six weakly positive samples by SRA (average release 56%) were WBIA negative. When these samples were retested using a random donor, only two remained SRA positive. Three samples were strongly WBIA positive but SRA negative; two were retested by SRA with 0.5IU/ml heparin and one became positive. Under controlled conditions, using the same selected high-responder donor, WBIA and SRA performed similarly with slightly increased sensitivity of the WBIA when using the strict definition of SRA positivity. WBIA is easy to perform with rapid turn-around time and warrants a multi-laboratory trial to complete its validation as a confirmatory assay for platelet-activating HIT antibodies.Keywords
This publication has 48 references indexed in Scilit:
- Simple Scoring System for Early Management of Heparin-Induced ThrombocytopeniaClinical and Applied Thrombosis/Hemostasis, 2010
- Validation of the high-dose heparin confirmatory step for the diagnosis of heparin-induced thrombocytopeniaBlood, 2010
- Thrombin generation and heparin‐induced thrombocytopeniaJournal of Thrombosis and Haemostasis, 2009
- False‐positive tests for heparin‐induced thrombocytopenia in patients with antiphospholipid syndrome and systemic lupus erythematosusJournal of Thrombosis and Haemostasis, 2009
- Antiphospholipid and anti‐PF4 antibodies: an association affecting anti‐PF4/heparin assay analysisJournal of Thrombosis and Haemostasis, 2009
- Laboratory testing for heparin-induced thrombocytopenia is inconsistent in North America: A survey of North American specialized coagulation laboratoriesThrombosis and Haemostasis, 2007
- Multiple electrode aggregometry: A new device to measure platelet aggregation in whole bloodThrombosis and Haemostasis, 2006
- A diagnostic test for heparin‐induced thrombocytopenia: detection of platelet microparticles using flow cytometryBritish Journal of Haematology, 1996
- A single amino acid distinguishes the high‐responder from the low‐responder form of Fc receptor II on human monocytesEuropean Journal of Immunology, 1991
- Heparin‐induced Thrombocytopenia: Effect of Heparin Platelet Antibody on PlateletsBritish Journal of Haematology, 1981