Evaluation of Treatment Systems for the Removal of Arsenic from Groundwater

Authors:

Abstract
High concentrations of iron and arsenic are common in Saskatchewan groundwater. Their cost effective removal from groundwater is a challenge for small communities. Four small treatment systems were tested for iron and arsenic removal with and without ozone pretreatment using groundwater high in iron (6.4–8.4 mg∕L) and arsenic (14.5–27.2 μg∕L) . The systems tested were (1) coagulation, (2) biological activated carbon (BAC) filter, (3) slow sand filter, and (4) rapid sand filter. Coagulation removed 70% of arsenic and 85% of iron. With ozone pretreatment, the removal increased to 95% for arsenic and 93% for iron. The BAC system was highly effective in the removal of both arsenic and iron. On average, it removed 97% of arsenic and 99.8% of iron. With the ozone pretreatment, the average removal increased to 99% for arsenic and 99.9% for iron. The increase in iron removal with ozone was not statistically significant at P=0.1 . The slow sand filter system was also highly effective in the removal of both arsenic...

This publication has 34 references indexed in Scilit: