Virtual reality–based 3-dimensional localization of stereotactic EEG (SEEG) depth electrodes and related brain anatomy in pediatric epilepsy surgery
- 30 October 2021
- journal article
- research article
- Published by Springer Nature in Child's Nervous System
- Vol. 38 (3) , 537-546
Abstract
Introduction The increasing use of stereoelectroencephalography (SEEG) in the USA and the need for three-dimensional (3D) appreciation of complex spatial relationships between implanted stereotactic EEG depth electrodes and surrounding brain and cerebral vasculature are a challenge to clinicians who are used to two-dimensional (2D) appreciation of cortical anatomy having been traditionally trained on 2D radiologic imaging. Virtual reality and its 3D renderings have grown increasingly common in the multifaceted practice of neurosurgery. However, there exists a paucity in the literature regarding this emerging technology in its utilization of epilepsy surgery. Methods An IRB-approved, single-center retrospective study identifying all SEEG pediatric patients in which virtual reality was applied was observed. Results Of the 46 patients identified who underwent an SEEG procedure, 43.5% (20/46) had a 3D rendering (3DR) of their SEEG depth electrodes. All 3DRs were used during patient-family education and discussion among the Epilepsy multidisciplinary team meetings, while 35% (7/20) were used during neuronavigation in surgery. Three successful representative cases of its application were presented. Discussion Our institution’s experience regarding virtual reality in the 3D representation of SEEG depth electrodes and the application to pre-surgical planning, patient-family education, multidisciplinary communication, and intraoperative neuronavigation demonstrate its applicability in comprehensive epilepsy patient care.Keywords
This publication has 22 references indexed in Scilit:
- Is the use of Stereotactic Electroencephalography Safe and Effective in Children? A Meta-Analysis of the use of Stereotactic Electroencephalography in Comparison to Subdural Grids for Invasive Epilepsy Monitoring in Pediatric SubjectsNeurosurgery, 2018
- Safety and efficacy of stereoelectroencephalography in pediatric focal epilepsy: a single-center experienceJournal of Neurosurgery: Pediatrics, 2018
- Stereoelectroencephalography in children: a reviewNeurosurgical Focus, 2018
- Robot-Assisted Responsive Neurostimulator System Placement in Medically Intractable Epilepsy: Instrumentation and TechniqueOperative Neurosurgery, 2018
- Virtual Reality and Simulation in Neurosurgical TrainingWorld Neurosurgery, 2017
- Endoscopic Endonasal Approach for Transclival Resection of a Petroclival Meningioma: A Technical NoteCureus, 2016
- The Stereo-Electroencephalography MethodologyNeurosurgery Clinics of North America, 2016
- Stereoelectroencephalography in Children and Adolescents With Difficult-to-Localize Refractory Focal EpilepsyNeurosurgery, 2014
- Man, Mind, and Machine: The Past and Future of Virtual Reality Simulation in Neurologic SurgeryWorld Neurosurgery, 2011
- Localization of Implanted EEG Electrodes in a Virtual-Reality EnvironmentComputer Aided Surgery, 2001