Abstract
A biodegradable coronary stent is expected to eliminate the adverse events of an otherwise eternally implanting material after vessel remodeling. Both biocorrodible metals and biodegradable polymers have been tried as the matrix of the new generation stent. Herein, we utilized a metal-polymer composite material to combine the advantages of the high mechanical strength of metals and the adjustable degradation rate of polymers to prepare the biodegradable stent. After coating polylactide (PLA) on the surface of iron, the degradation of iron was accelerated significantly owing to the decrease of local pH resulting from the hydrolysis of PLA, etc. We implanted the metal-polymer composite stent (MPS) into the porcine artery and examined its degradation in vivo, with the corresponding metal-based stent (MBS) as a control. Microcomputed tomography (micro-CT), coronary angiography, and optical coherence tomography (OCT) were performed to observe the stents and vessels during the animal experiments. The MPS exhibited faster degradation than MBS, and the inflammation response of MPS was acceptable 12 months after implantation. Additionally, we implanted another MPS after one-year implantation of the first MPS to investigate the result of MPS in the second implantation. The feasibility of the biodegradable MPS in second implantation in mammals was also confirmed.Keywords
Funding Information
- Ministry of Science and Technology of the People's Republic of China (2016YFC1100300, 2018YFC1106600)
- Science and Technology Commission of Shanghai Municipality (17JC1400200)
- National Natural Science Foundation of China (2191101058, 51533002)
This publication has 67 references indexed in Scilit:
- In vivo and in vitro tracking of erosion in biodegradable materials using non-invasive fluorescence imagingNature Materials, 2011
- Biodegradable Metals for Cardiovascular Stent Application: Interests and New OpportunitiesInternational Journal of Molecular Sciences, 2011
- In-Stent Restenosis in the Drug-Eluting Stent EraJACC, 2010
- Coronary-Artery StentsNew England Journal of Medicine, 2006
- Impact of strut thickness on late luminal loss after coronary artery stent placementThe American Journal of Cardiology, 2004
- Coronary Restenosis After Sirolimus-Eluting Stent ImplantationCirculation, 2003
- Disorders of Iron MetabolismNew England Journal of Medicine, 1999
- A Biodegradable Poly‐l‐lactic Acid Coronary Stent in the Porcine Coronary ArteryJournal of Interventional Cardiology, 1999
- Biocompatibility studies on surgical‐grade titanium‐, cobalt‐, and iron‐base alloysJournal of Biomedical Materials Research, 1976
- Potential-pH Diagram of Lead and its Applications to the Study of Lead Corrosion and to the Lead Storage BatteryJournal of the Electrochemical Society, 1951