Abstract
The two-phase distribution in helical coil steam generators (HCSGs) plays an important role in determining thermal–hydraulic behavior, as it affects interfacial transport characteristics and the overall pressure drop. To investigate curvature-induced driving force on helical coil tubes and its effect on the two-phase distribution, an air-water visualization experiment was conducted using a wire-mesh sensor (WMS). Flow structure visualization using WMS enabled direct observation, including bubble shape and their spatial distribution. It is observed that centrifugal force modifies the buoyant force direction, resulting in a different pattern compared to the straight tube results. In addition, secondary flow promotes lateral migration of bubbles perpendicular to the axial direction. This secondary flow effect flattens cross-sectional phase distribution, delaying stable bubble blanket formation, which potentially degrades local heat transfer. The resulting data can serve as a useful validation database for computational fluid dynamics (CFD) simulations.