Impact of raising the upper extremity siding cardiac implantable electrical devices on postoperative safety
Open Access
- 15 June 2023
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (4) , 586-595
Abstract
BackgroundThe upper extremity siding cardiac implantable electrical device tends to have a limited range of motion during the perioperative period; however, the underlying reason lacks scientific evidence. This study aimed to investigate the safety of the two methods (stepwise or early) of postoperative early upper extremity rehabilitation. MethodsWe retrospectively investigated 650 consecutive patients with a new implantable pacemaker (PM), implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy (CRT), or generator exchange between March 2017 and December 2020.The limitation program was conducted from March 2017 to March 2018. The intervention program started as a stepwise protocol in April 2018 and was switched to an early protocol in December 2019. ResultsThis study analyzed 591 patients, excluding 59 who met the exclusion criteria. The mean age was 76.0 (69.0-82.0) years; 412 (69.7%) patients had a PM, 79 (13.4%) had an ICD, and 100 (16.9%) utilized CRT. There were 155 patients in the limitation protocol, 251 in the stepwise protocol, and 185 patients in the early protocol groups. Postoperative complications occurred in 53 (9.0%) patients. There was no significant difference in the incidence of all complications between the three groups (16 patients [10.3%] vs. 26 patients [10.4%] vs. 11 patients [5.9%]). Shoulder exercise-related complications were defined as hematoma (p = .94), lead dislodgement (p = .16), and increased pacing threshold (p = .23). General complications included wound infection (p = .51), pneumothorax (p = .27), tamponade (p = .07), and deep venous thrombosis (p = .26). ConclusionRaising of the upper extremity siding cardiac implantable electrical devices above the head did not compromise postoperative safety.Keywords
This publication has 24 references indexed in Scilit:
- Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing populationOpen Heart, 2014
- Techniques of Pacemaker Implantation and Removal2014
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in ItalyEP Europace, 2013
- Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009JACC, 2012
- Preventing Shoulder Pain after Cardiac Rhythm Management Device Implantation: A Randomized, Controlled StudyPacing and Clinical Electrophysiology, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- 50th Anniversary of the First Successful Permanent Pacemaker Implantation in the United States: Historical Review and Future DirectionsThe American Journal of Cardiology, 2010
- Dual Antiplatelet Therapy and Heparin “Bridging” Significantly Increase the Risk of Bleeding Complications After Pacemaker or Implantable Cardioverter-Defibrillator Device ImplantationJACC, 2010
- Temporal trends in permanent pacemaker implantation: A population-based studyAmerican Heart Journal, 2008