Performance of 45-year-old corroded prestressed concrete beams
Authors:
- 1 November 2013
- journal article
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 166 (10) , 547-559
Abstract
The design of prestressed concrete bridge beams usually assumes that the full capacity of the tendons can be achieved under ultimate load, based on the assumption of sufficient deformation capacity of the prestressing wires. Whether this is achieved also in older bridges is of increasing interest in remaining-life assessments since, especially in aggressive marine environments, corrosion of steel is known to cause loss of wire ductility. Results are reported herein of load tests to destruction for three full-sized and deteriorated prestressed concrete bridge beams recovered from a 45-year-old bridge exposed to an aggressive marine environment. The two beams with the greatest superficial deterioration showed progressive and premature failure of the prestressing wires. The beam with little superficial deterioration also showed progressive failure and failed to reach the ultimate load capacity based on current design theory and actual material properties. Possible reasons for the observed behaviour and the practical implications are discussed.Keywords
This publication has 19 references indexed in Scilit:
- Hydrogen embrittlement of prestressing cablesCorrosion Science, 2010
- The effects of corrosion on 45-year-old pre-stressed concrete bridge beamsStructure and Infrastructure Engineering, 2010
- Observations and analysis of a 63-year-old reinforced concrete promenade railing exposed to the North SeaMagazine of Concrete Research, 2009
- Assessment of the stress corrosion cracking in a chloride medium of cables used in prestressed concrete structures by the acoustic emission techniqueMeasurement Science and Technology, 2008
- Spatial time-dependent reliability analysis of corroding pretensioned prestressed concrete bridge girdersStructural Safety, 2007
- A residual strength model for deteriorating post-tensioned concrete bridgesComputers & Structures, 2001
- Load carrying capacity of concrete structures with corroded reinforcementConstruction and Building Materials, 1997
- Effect of cold drawing on susceptibility to hydrogen embrittlement of prestressing steelMaterials and Structures, 1993
- COLLAPSE OF YNS-Y-GWAS BRIDGE, GLAMORGAN.Proceedings of the Institution of Civil Engineers, 1988
- Pitting, crevice and stress corrosion cracking studies of cold drawn eutectoid steelsCorrosion Science, 1980