Factors affecting pediatric isotonic fluid resuscitation efficiency: a randomized controlled trial evaluating the impact of syringe size
Open Access
- 24 July 2013
- journal article
- research article
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 13 (1) , 14
Abstract
Background: Goal-directed therapy guidelines for pediatric septic shock resuscitation recommend fluid delivery at speeds in excess of that possible through use of regular fluid infusion pumps. In our experience, syringes are commonly used by health care providers (HCPs) to achieve rapid fluid resuscitation in a pediatric fluid resuscitation scenario. At present, it is unclear which syringe size health care providers should use when performing fluid resuscitation to achieve maximal fluid resuscitation efficiency. The objective of this study was therefore to determine if an optimal syringe size exists for conducting manual pediatric fluid resuscitation. Methods: This 48-participant parallel group randomized controlled trial included 4 study arms (10, 20, 30, 60 mL syringe size groups). Eligible participants were HCPs from McMaster Children’s Hospital, Hamilton, Canada blinded to the purpose of the trial. Consenting participants were randomized using a third party technique. Following a standardization procedure, participants administered 900 mL (60 mL/kg) of isotonic saline to a simulated 15 kg child using prefilled provided syringes of the allocated size in rapid sequence. Primary outcome was total time to administer the 900 mL and this data was collected through video review by two blinded outcome assessors. Sample size was predetermined based upon a primary outcome analysis using one-way ANOVA. Results: 12 participants were randomized to each group (n=48) and all completed trial protocol to analysis. Analysis was conducted according to intention to treat principles. A significant difference in fluid resuscitation time (in seconds) was found between syringe size group means: 10 mL, 563s [95% CI 521; 606]; 20 mL, 506s [95% CI 64; 548]; 30 mL, 454s [95% CI 412; 596]; 60 mL, 455s [95% CI 413; 497] (p<0.001). Conclusions: The syringe size used when performing manual pediatric fluid resuscitation has a significant impact on fluid resuscitation speed, in a setting where fluid filled syringes are continuously available. Greatest efficiency was achieved with 30 or 60 mL syringes. Trial registration: ClinicalTrials.gov, NCT01494116Keywords
This publication has 18 references indexed in Scilit:
- Translating Resuscitation Guidelines into Practice: Health Care Provider Attitudes, Preferences and Beliefs Regarding Pediatric Fluid Resuscitation PerformancePLOS ONE, 2013
- http://www.journalmtm.com/2012/use-of-a-tablet-to-enhance-standardisation-procedures-in-a-randomised-trial/Journal of Mobile Technology in Medicine, 2012
- Mortality after Fluid Bolus in African Children with Severe InfectionNew England Journal of Medicine, 2011
- Part 14: Pediatric Advanced Life SupportCirculation, 2010
- Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine*Critical Care Medicine, 2009
- Time- and Fluid-Sensitive Resuscitation for Hemodynamic Support of Children in Septic ShockPediatric Emergency Care, 2008
- Rapid Fluid Resuscitation in Pediatrics: Testing the American College of Critical Care Medicine GuidelineAnnals of Emergency Medicine, 2007
- Fluid Resuscitation of Hypovolemic Shock: Acute Medicine's Great Triumph for ChildrenIntensive Care Medicine, 2006
- Aggressive management of dengue shock syndrome may decrease mortality rate: A suggested protocol*Pediatric Critical Care Medicine, 2005
- An evaluation of the Rapid Infusion SystemAnaesthesia, 1992