Abstract
The syngas production step is one of the most costly steps in a gas‐to‐liquid plant. Commonly, oxygen is used as an oxidant in the reforming step. However, through the introduction of microchannel reactors, the use of enriched air may be justified. The merits of using enriched air versus pure oxygen are analyzed by utilizing an autothermal reformer, with microchannel reactors in the once‐through Fischer‐Tropsch (FT) step. Pure oxygen is provided by a cryogenic air separation unit (ASU) and enriched air by use of air separation membranes. Pure oxygen requires a smaller FT reactor volume, which means lower reactor costs at the expense of having a costly cryogenic ASU to produce pure oxygen. The operating cost of the ASU is lower than that of the air membrane, but the installed cost is higher.
Funding Information
  • Norges Forskningsråd (10403101)

This publication has 12 references indexed in Scilit: