Highly efficient respiratory motion compensated free‐breathing coronary mra using golden‐step Cartesian acquisition
Open Access
- 27 February 2014
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (3) , 738-746
Abstract
Purpose: To develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole‐heart coronary magnetic resonance angiography (MRA).Materials and Methods: The proposed method achieves 100% scan efficiency by estimating the affine respiratory motion from the data itself and correcting the acquired data in the reconstruction process. For this, a golden‐step Cartesian sampling with spiral profile ordering was performed to enable reconstruction of respiratory resolved images at any breathing position and with different respiratory window size. Affine motion parameters were estimated from image‐based registration of 3D undersampled respiratory resolved images reconstructed with iterative SENSE and motion correction was performed directly in the reconstruction using a multiple‐coils generalized matrix formulation method. This approach was tested on healthy volunteers and compared against a conventional diaphragmatic navigator‐gated acquisition using quantitative and qualitative image quality assessment.Results: The proposed approach achieved 47 ± 12% and 59 ± 6% vessel sharpness for the right (RCA) and left (LAD) coronary arteries, respectively. Also, good quality visual scores of 2.4 ± 0.74 and 2.44 ± 0.86 were observed for the RCA and LAD (scores from 0, no to 4, excellent coronary vessel delineation). A not statically significant difference (P = 0.05) was found between the proposed method and an 8‐mm navigator‐gated and tracked scan, although scan efficiency increased from 61 ± 10% to 100%.Conclusion: We demonstrate the feasibility of a new 3D affine respiratory motion correction technique for Cartesian whole‐heart CMRA that achieves 100% scan efficiency and therefore a predictable acquisition time. This approach yields image quality comparable to that of an 8‐mm navigator‐gated acquisition with lower scan efficiency. Further evaluation of this technique in patients is now warranted to determine its clinical use. J. Magn. Reson. Imaging 2015;41:738–746. © 2014 Wiley Periodicals, Inc.Keywords
This publication has 30 references indexed in Scilit:
- Respiratory self‐navigation for whole‐heart bright‐blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood poolMagnetic Resonance in Medicine, 2011
- Subject‐specific estimation of respiratory navigator tracking factor for free‐breathing cardiovascular MRMagnetic Resonance in Medicine, 2011
- A respiratory self‐gating technique with 3D‐translation compensation for free‐breathing whole‐heart coronary MRAMagnetic Resonance in Medicine, 2009
- Non‐model‐based correction of respiratory motion using beat‐to‐beat 3D spiral fat‐selective imagingJournal of Magnetic Resonance Imaging, 2007
- Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstructionMagnetic Resonance in Medicine, 2005
- Respiratory Motion of the Heart From Free Breathing Coronary AngiogramsIEEE Transactions on Medical Imaging, 2004
- Respiratory motion in coronary magnetic resonance angiography: A comparison of different motion modelsJournal of Magnetic Resonance Imaging, 2002
- Calculation of a Subject-Specific Adaptive Motion-Correction Factor for Improved Real-Time Navigator Echo-Gated Magnetic Resonance Coronary AngiographyJournal of Cardiovascular Magnetic Resonance, 1999
- Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.Radiology, 1996
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995