Rapid multiplanar abdominal survey using MRI with the steady-state free-precession technique
Open Access
- 1 January 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (1) , 198-203
Abstract
Purpose To retrospectively evaluate the sensitivity, specificity, and positive and negative predictive values of steady‐state free‐precession (SSFP) survey MRI of the abdomen. Materials and Methods A total of 375 consecutive outpatients underwent abdominal MRI at 1.5T. Excluding diffuse metastatic disease, 110 patients had at least one other clinically important finding. The SSFP survey included contiguous 5‐mm‐thick axial, sagittal, and coronal slices (total 90 slices) obtained during a total of 90 seconds of free breathing. Studies were reviewed by two experienced MRI readers independently, randomized, blinded, and at different sittings. The chi‐squared test was used to compare SSFP to full MRI for showing clinically important findings. In a subset of 30 patients, confidence intervals (CI) were calculated to compare the accuracy of SSFP and full MRI as predictors of biopsy result. Results SSFP detected 87.3% of clinically important findings and 93.3% of malignancies reported on the full MRI, with a 1.5% false‐positive rate. Significant association was shown between SSFP and full MRI for clinically important findings (P < 0.0001). Compared to biopsy, accuracy of SSFP was high (85% ± 12.7%), though not as high as full MRI (93.3% ± 8.8%). Conclusion SSFP provides a rapid survey of the abdomen, with good sensitivity and few false positives. J. Magn. Reson. Imaging 2007.Keywords
This publication has 23 references indexed in Scilit:
- Radiology clinical synopsis: a simple solution for obtaining an adequate clinical history for the accurate reporting of imaging studies on patients in intensive care unitsPediatric Radiology, 2005
- Water‐saturated three‐dimensional balanced steady‐state free precession for fast abdominal fat quantificationJournal of Magnetic Resonance Imaging, 2005
- Accuracy of Diagnostic Tests Read With and Without Clinical InformationJAMA, 2004
- TrueFISP—technical considerations and cardiovascular applicationsEuropean Journal of Radiology, 2003
- Cardiac Function: MR Evaluation in One Breath Hold with Real-time True Fast Imaging with Steady-State PrecessionRadiology, 2002
- Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State PrecessionRadiology, 2001
- IMAGING TECHNIQUES: Cardiovascular magnetic resonanceHeart, 2001
- MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility StudyRadiology, 2001
- The influence of clinical information on the reporting of CT by radiologists.British Journal of Radiology, 2000
- Single Breath-Holding Scans of the Abdomen Using FISP and FLASH at 1.5 TJournal of Computer Assisted Tomography, 1988