Evaluation of high‐throughput digital lateral flow immunoassays for the detection of influenza A/B viruses from clinical swab samples
- 7 November 2019
- journal article
- research article
- Published by Wiley in Journal of Medical Virology
- Vol. 92 (8) , 1040-1046
Abstract
We evaluated the performance of new high‐throughput digital lateral flow immunoassays (LFIAs) detecting influenza antigens and compared them with those of the widely used digital LFIA and the rapid nucleic acid amplification test (NAAT). We tested 199 clinical nasopharyngeal (nasal) swab samples using three LFIA tests (BD Veritor Plus, STANDARD F Influenza A/B FIA, and ichroma TRIAS) and the rapid NAAT (ID NOW Influenza A & B2). Agreements and clinical performances (sensitivity and specificity) were evaluated based on the results of reverse transcriptase‐polymerase chain reaction (RT‐PCR) and verification panel. The agreement of each test with RT‐PCR was moderate to almost perfect. The sensitivity of ID NOW was significantly higher than that of LFIAs (P = .0005, .0044, and .0026 for influenza A and P = .0044, .0026, and .0044 for influenza B, respectively). The specificities were not significantly different between the four tests (P > .05). However, the reference panel suggests that ichroma TRIAS test is more sensitive than the other two LFIA tests. All three LFIA assays performed similarly with no false positives against influenza A. For influenza B, ichroma TRIAS had 2 of 166 false positives whereas there were no false positives for the other two LFIA tests. Influenza antigen digital LFIAs have advantages in terms of the workflow when simultaneous tests are required. Rapid NAAT has higher sensitivity, while new antigen LFIAs are efficient and high‐throughput. It is recommended that users select appropriate methods and algorithms according to the number of specimens and laboratory conditions in each clinical laboratory.Keywords
This publication has 29 references indexed in Scilit:
- A prospective study to assess the diagnostic performance of the Sofia® Immunoassay for Influenza and RSV detection.Journal of Clinical Virology, 2016
- Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test stripsAnalytica Chimica Acta, 2015
- Socioeconomic Burden of Influenza in the Republic of Korea, 2007–2010PLOS ONE, 2013
- A National Study of the Impact of Rapid Influenza Testing on Clinical Care in the Emergency DepartmentJournal of the Pediatric Infectious Diseases Society, 2013
- Accuracy of Rapid Influenza Diagnostic TestsAnnals of Internal Medicine, 2012
- Lanthanide-based time-resolved luminescence immunoassaysAnalytical and Bioanalytical Chemistry, 2011
- Outbreak of Swine-Origin Influenza A (H1N1); Experience of a Regional Center in Seoul during a Month, August-September 2009Korean Journal of Clinical Microbiology, 2010
- Lateral Flow Immunoassay Using Europium Chelate-Loaded Silica Nanoparticles as LabelsClinical Chemistry, 2009
- Rapid diagnosis of influenza infection in older adults: Influence on clinical care in a routine clinical settingJournal of Clinical Virology, 2008
- Accuracy of Clinical Diagnosis of Influenza in Outpatient ChildrenClinical Infectious Diseases, 2005