Typical within and between person variability in non-invasive ventilator derived variables among clinically stable, long-term users
Open Access
- 4 March 2021
- journal article
- research article
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 8 (1) , e000824
Abstract
Background: Despite increasing capacity to remotely monitor non-invasive ventilation (NIV), how remote data varies from day to day and person to person is poorly described. Methods: Single-centre, 2-month, prospective study of clinically stable adults on long-term NIV which aimed to document NIV-device variability. Participants were switched to a ventilator with tele-monitoring capabilities. Ventilation settings and masking were not altered. Raw, extensible markup language data files were provided directly from Philips Respironics (EncoreAnywhere). A nested analysis of variance was conducted on each ventilator variable to apportion the relative variation between and within participants. Results: Twenty-nine people were recruited (four withdrew, one had insufficient data for analyses; 1364 days of data). Mean age was 54.0 years (SD 18.4), 58.3% male with body mass index of 37.0 kg/m2 (13.7). Mean adherence was 8.53 (2.23) hours/day and all participants had adherence >4 hours/day. Variance in ventilator-derived indices was predominantly driven by differences between participants; usage (61% between vs 39% within), Apnoea–Hypopnoea Index (71% vs 29%), unintentional (64% vs 36%) and total leak (83% vs 17%), tidal volume (93% vs 7%), minute ventilation (92% vs 8%), respiratory rate (92% vs 8%) and percentage of triggered breaths (93% vs 7%). Interpretation: In this clinically stable cohort, all device-derived indices were more varied between users than the day-to-day variation within individuals. We speculate that normative ranges and thresholds for clinical intervention need to be individualised, and further research is necessary to determine the clinically important relationships between clinician targets for therapy and patient-reported outcomes.Keywords
This publication has 31 references indexed in Scilit:
- Home Mechanical Ventilation through Mask: Monitoring Leakage and Nocturnal Oxygenation at HomeRespiration, 2012
- Home mechanical ventilation in Australia and New ZealandEuropean Respiratory Journal, 2012
- The Impact of a Telemedicine Monitoring System on Positive Airway Pressure Adherence in Patients with Obstructive Sleep Apnea: A Randomized Controlled TrialSLEEP, 2012
- The accuracy of autotitrating CPAP-determined residual apnea–hypopnea indexSleep and Breathing, 2012
- Home telemonitoring of non-invasive ventilation decreases healthcare utilisation in a prospective controlled trial of patients with amyotrophic lateral sclerosisJournal of Neurology, Neurosurgery & Psychiatry, 2010
- Effect of manufacturer-inserted mask leaks on ventilator performanceEuropean Respiratory Journal, 2009
- Effect of sleep on patient/ventilator asynchrony in patients undergoing chronic non-invasive mechanical ventilationRespiratory Medicine, 2007
- Noninvasive positive-pressure ventilation in ALSNeurology, 2006
- Effects of Gas Leak on Triggering Function, Humidification, and Inspiratory Oxygen Fraction During Noninvasive Positive Airway Pressure VentilationChest, 2005
- Mechanisms of improvement of respiratory failure in patients with restrictive thoracic disease treated with non-invasive ventilationThorax, 2005