Behaviours of three‐dimensional compressive and tensile forces exerted on a tooth during function
Authors:
- 16 March 2007
- journal article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 34 (4) , 259-266
Abstract
The 3-D tensile and compressive forces exerted on a tooth were measured in vivo during function using a force-measuring device including a piezoelectric transducer. The device was mounted on the maxillary left second molar of a healthy male subject; the subject tooth had been endodontically treated and prepared for metal abutment and a crown. The 3-D forces were expressed as a vector of the coordinates based on the Frankfort horizontal (x-y) and sagittal (y-z) planes. The device captured the sequential changes in the forces. The directions of the forces changed during not only chewing a caramel or a peanut but also maximum voluntary clenching (MVC). As the magnitudes of the force increased during both MVC and caramel chewing (CaC), the force vector tended to correspond to the direction of the palatal root, medially and posteriorly. The compressive forces during MVC and caramel and peanut chewing were 173.29+/-15.32, 146.3+/-14.7 and 57.7+/-35.7 N, respectively. The force vector during MVC was directed from the crown to the root medially at an angle of 10.27+/-1.00 degrees from the y-z plane and posteriorly at an angle of 3.18+/-0.85 degrees from the x-z plane to the perpendicular line of the F-H plane. There were significant differences in the behaviour of the compressive forces between clenching and chewing. The tensile force was recorded during CaC, not peanut chewing.Keywords
This publication has 24 references indexed in Scilit:
- Functional properties and regional differences of human masseter motor units related to three‐dimensional bite forceJournal of Oral Rehabilitation, 2006
- Stresses at the cervical lesion of maxillary premolar—a finite element investigationJournal of Dentistry, 2002
- Force distribution on implants supporting overdentures: the effect of distal bar extensions. A 3‐D in viva study.Clinical Oral Implants Research, 1997
- Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo. A methodological study.Clinical Oral Implants Research, 1996
- Patterns of jaw muscle activity during voluntary chewingJournal of Oral Rehabilitation, 1996
- Electromyographic Heterogeneity in the Human Masseter MuscleJournal of Dental Research, 1992
- Medial pterygoid muscle activity during the closing and compressive phases of human masticationAmerican Journal of Physical Anthropology, 1981
- The effect of bite force on the duration and latency of the menton tap silent periodJournal of Oral Rehabilitation, 1981
- Analysis of Stress Patterns in the Human MandibleJournal of Dental Research, 1975
- Measurement of Strains in Fixed Bridges with Electronic Strain GaugesJournal of Dental Research, 1967