Evaluation of Iodine-Based Contrast Agents for Micro-Computed Tomography Imaging of Porcine Cardiac Conduction System
Preprint
Abstract
Purpose: This study compares two iodine-based contrast agents, iodine in ethanol (I2E) and aqueous solution of potassium triiodide (I2KI), in optimizing high-resolution, contrast-enhanced micro computed tomography imaging (micro-CT) of the cardiac conduction system (CCS) in porcine hearts. The study evaluates their relative efficacy in enhancing tissue contrast and anatomical delineation, aiming to improve CCS visualization for advanced cardiac research. Methods: Dissected porcine hearts were stained with I2E or I2KI for contrast enhancement and scanned with micro-computed tomography. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and volumetric shrinkage were evaluated. Additionally, qualitative visualization of CCS-related anatomical landmarks, such as the sinoatrial node (SAN), atrioventricular node (AVN), and Purkinje fibres, was performed, along with assessment of artefact occurrence and sample integrity. The efficacy of the contrast agents was also determined by segmenting the regions of interest corresponding to the CCS from micro-CT images. These were then further validated against histology. Results: I2E provided superior CNR, fewer artefacts, and preserved sample integrity, enabling smooth post-processing and histological sectioning. I2KI staining produced higher soft-tissue signal intensity and faster stain saturation (day 2) than I2E (day 3). However, I2KI exhibited leaching and introduced substantial staining artefacts. I2KI also exhibited structural disintegration, which, in turn, compromised downstream processing. Conclusion: These results suggest that I2E is a viable alternative to I2KI for CCS micro-CT imaging when sample preservation and downstream analyses are essential, whereas I2KI may be preferred for rapid, high-intensity staining where tissue integrity is less critical.Keywords
Funding Information
- Research Council of Finland (Flagship of Advanced Mathematics for Sensing Imaging and Modelling) (359186)
This publication has 32 references indexed in Scilit:
- 3D Histopathology of Musculoskeletal Tissues Using Contrast-Enhanced Micro-computed Tomography2025
- Rotating Frame Relaxation Time Mapping for the Visualization of the Sinoatrial Node Without Contrast AgentNMR in Biomedicine, 2025
- Quantitative magnetic resonance imaging of the atrioventricular conduction axis based on the rotating-frame relaxation maps: Comparison with T2, T1, and magnetization transferHeart Rhythm, 2025
- Screening staining agents for contrast-enhanced microCT of vascular tissues: Assessing the effect on microstructural and mechanical propertiesTomography of Materials and Structures, 2024
- Exploring contrast-enhancing staining agents for studying adipose tissue through contrast-enhanced computed tomographyJournal of Lipid Research, 2024
- Development and validation of the effective CNR analysis method for evaluating the contrast resolution of CT imagesPhysical and Engineering Sciences in Medicine, 2024
- Evaluation of the Effect of Iodine Staining and Sodium Thiosulfate Clearing on the Quality of X-ray Microtomographic Images and Histological Processing of Small Bowel Biopsies2024
- Novel micro-computed tomography contrast agents to visualise the human cardiac conduction system and surrounding structures in hearts from normal, aged, and obese individualsTranslational Research in Anatomy, 2022
- Combining micro-computed tomography with histology to analyze biomedical implants for peripheral nerve repairJournal of Neuroscience Methods, 2015
- Iodine‐enhanced micro‐CT imaging: Methodological refinements for the study of the soft‐tissue anatomy of post‐embryonic vertebratesJournal of Experimental Zoology Part B: Molecular and Developmental Evolution, 2014