PPGnet: Deep Network for Device Independent Heart Rate Estimation from Photoplethysmogram
Authors:
- S.P. PreejithSPS.P. Preejith
- 1 July 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 1899-1902
Abstract
Photoplethysmogram (PPG) is increasingly used to provide monitoring of the cardiovascular system under ambulatory conditions. Wearable devices like smartwatches use PPG to allow long-term unobtrusive monitoring of heart rate in free-living conditions. PPG based heart rate measurement is unfortunately highly susceptible to motion artifacts, particularly when measured from the wrist. Traditional machine learning and deep learning approaches rely on tri-axial accelerometer data along with PPG to perform heart rate estimation. The conventional learning based approaches have not addressed the need for device-specific modeling due to differences in hardware design among PPG devices. In this paper, we propose a novel end-to-end deep learning model to perform heart rate estimation using 8-second length input PPG signal. We evaluate the proposed model on the IEEE SPC 2015 dataset, achieving a mean absolute error of 3.36±4.1BPM for HR estimation on 12 subjects without requiring patient-specific training. We also studied the feasibility of applying transfer learning along with sparse retraining from a comprehensive in-house PPG dataset for heart rate estimation across PPG devices with different hardware design.Keywords
All Related Versions
This publication has 13 references indexed in Scilit:
- ECGNet: Deep Network for Arrhythmia Classification2018
- Computationally efficient heart rate estimation during physical exercise using photoplethysmographic signals2017
- Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise CancellationIEEE Journal of Biomedical and Health Informatics, 2016
- Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer LearningIEEE Transactions on Medical Imaging, 2016
- A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram SensorSensors, 2015
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- Cancellation of motion artifact induced by exercise for PPG-based heart rate sensing2014
- Evaluation of wearable consumer heart rate monitors based on photopletysmography2014
- The finger volume pulse and assessment of arterial propertiesJournal Of Hypertension, 2002
- The ‘Trier Social Stress Test’ – A Tool for Investigating Psychobiological Stress Responses in a Laboratory SettingNeuropsychobiology, 1993