Whole Body Postmortem Angiography with a High Viscosity Contrast Agent Solution Using Poly Ethylene Glycol as Contrast Agent Dissolver
- 24 March 2008
- journal article
- Published by Wiley in Journal of Forensic Sciences
- Vol. 53 (2) , 465-468
Abstract
Abstract: Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.Keywords
This publication has 13 references indexed in Scilit:
- Postmortem Angiography After Vascular Perfusion with Diesel Oil and a Lipophilic Contrast AgentAmerican Journal of Roentgenology, 2006
- VIRTOPSY: Minimally Invasive, Imaging-guided Virtual AutopsyRadioGraphics, 2006
- Reduction of Postmortem Angiography‐Induced Tissue Edema by Using Polyethylene Glycol as a Contrast Agent DissolverJournal of Forensic Sciences, 2006
- Virtopsy: Postmortem Minimally Invasive Angiography Using Cross Section Techniques—Implementation and Preliminary ResultsJournal of Forensic Sciences, 2005
- Fatal steamer accident; blunt force injuries and drowning in post-mortem MSCT and MRIForensic Science International, 2005
- Virtopsy: postmortem imaging of the human heart in situ using MSCT and MRIForensic Science International, 2005
- VIRTOPSY—Scientific Documentation, Reconstruction and Animation in Forensic: Individual and Real 3D Data Based Geo-Metric Approach Including Optical Body/Object Surface and Radiological CT/MRI ScanningJournal of Forensic Sciences, 2005
- Visualization and Quantification of Air Embolism Structure by Processing Postmortem MSCT DataJournal of Forensic Sciences, 2004
- Der Einfluß des Kontrastmitteltyps auf das Arterienkaliber in der experimentellen AngiographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1969
- Technik der postmortalen Angiographie mit Berücksichtigung verwandter Methoden postmortaler Gefäßdarstellung1960