Protocol for Simultaneous EEG and fNIRS Measurement in Characterizing Brain State
- 31 December 2024
- journal article
- research article
- Published by Springer Nature in Phenomics
- Vol. 5 (2) , 219-237
Abstract
Multi-modal signal measurement is widely used in health monitoring and disease recognition, such as electroencephalography (EEG)-functional magnetic resonance imaging (fMRI), EEG-functional near-infrared spectroscopy (fNIRS), EEG-electrocardiograph (ECG), etc. The concurrent recording of EEG-fNIRS not only measures concentration changes of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR) of the cortical microcirculation blood vessels but also records electrical activities of the cerebral cortex in a relatively portable setting compared with EEG-fMRI and other patterns. This protocol proposes a standard operating procedure for the joint EEG-fNIRS measurement, including electrode placement, hardware, and software. In the signal process, artifacts' removal, EEG-fNIRS phenotypes extraction by software and self-developed algorithm ways, and data storage are involved. In addition, solutions to problems that may be encountered in this protocol are also presented. This protocol is expected to broaden the application of joint EEG-fNIRS measurement and gain a deeper understanding of the underlying neural activation pattern and mechanism of the brain.Keywords
Funding Information
- Shanghai Municipal Science and Technology Major Project (2017SHZDZX01)
This publication has 42 references indexed in Scilit:
- Dynamic weighted “small-world” graphical network establishment for fNIRS time-varying brain function analysisBiomedical Signal Processing and Control, 2021
- Removal of EOG artifacts from single channel EEG – An efficient model combining overlap segmented ASSA and ANCBiomedical Signal Processing and Control, 2020
- Electrode Placement Systems and Montages2019
- Functional Near Infrared Spectroscopy System Validation for Simultaneous EEG-FNIRS Measurements2019
- Chemistry for Positron Emission Tomography: Recent Advances in 11C‐, 18F‐, 13N‐, and 15O‐Labeling ReactionsAngewandte Chemie International Edition, 2019
- Simultaneous EEG–PET–fMRI measurements in disorders of consciousness: an exploratory study on diagnosis and prognosisJournal of Neurology, 2017
- Neural Adaptation to a Working Memory Task: A Concurrent EEG-fNIRS Study2015
- Combining EEG and fMRI2010
- Simultaneous event‐related potential and near‐infrared spectroscopic studies of semantic processingHuman Brain Mapping, 2004
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995