Relation between calcium burden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation
Open Access
- 27 March 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 18 (6) , 648-653
Abstract
Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major–minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity.Keywords
This publication has 20 references indexed in Scilit:
- Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving systemInternational Journal of Cardiology, 2013
- Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve ReplacementJACC, 2013
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document†European Heart Journal, 2012
- Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantationHeart, 2012
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: Impact of aortic cusp calcification on postoperative aortic regurgitationThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Effect of Experience on Results of Transcatheter Aortic Valve Implantation Using a Medtronic CoreValve SystemThe American Journal of Cardiology, 2011
- Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve functionEuropean Heart Journal, 2010
- Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve ProsthesisJACC: Cardiovascular Interventions, 2010
- Percutaneous Aortic Valve Implantation Retrograde From the Femoral ArteryCirculation, 2006