Full-scan accurate mass selectivity of ultra-performance liquid chromatography combined with time-of-flight and orbitrap mass spectrometry in hormone and veterinary drug residue analysis
- 1 March 2009
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 20 (3) , 451-463
Abstract
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF) and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500 and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective sample preparation is expected to aggravate this issue further.Keywords
This publication has 17 references indexed in Scilit:
- Introduction of HPLC/orbitrap mass spectrometry as screening method for doping controlJournal of Mass Spectrometry, 2008
- Residue analysis of veterinary drugs and growth-promoting agentsTrAC Trends in Analytical Chemistry, 2007
- Large Scale Pesticide Multiresidue Methods in Food Combining Liquid Chromatography– Time-of-Flight Mass Spectrometry and Tandem Mass SpectrometryAnalytical Chemistry, 2007
- A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometryAnalytica Chimica Acta, 2007
- Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Liquid chromatography with time-of-flight mass spectrometry for simultaneous determination of chemotherapeutant residues in salmonAnalytica Chimica Acta, 2006
- Isotopic pattern and accurate mass determination in urine drug screening by liquid chromatography/time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass SpectrometerAnalytical Chemistry, 2006
- Matrix effects on accurate mass measurements of low‐molecular weight compounds using liquid chromatography‐electrospray‐quadrupole time‐of‐flight mass spectrometryJournal of Mass Spectrometry, 2006
- Multi residue screening of intact testosterone esters and boldenone undecylenate in bovine hair using liquid chromatography electrospray tandem mass spectrometryJournal of Chromatography B, 2006