Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis
Authors:
- Luis Fernández-VegaLFLuis Fernández-Vega
- Begoña BaamondeBBBegoña Baamonde
- David Madrid-CostaDMDavid Madrid-Costa
- Robert Montés-MicóRMRobert Montés-Micó
- 1 June 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (6) , 1090-1096
Abstract
To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK). Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Cohort study. Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK. Under photopic conditions at 100% contrast, there were no statistically significant differences between the 2 groups (P > .01) and the CDVA was 0.1 logMAR or better (approximately 20/25) in both groups. At 25.0% and 12.5% contrast, there were no statistically significant differences between the 2 groups (P > .01). Under mesopic conditions, the control group had better CDVA than the study group without glare at all contrasts (P < .01). In the study group, the mean UNVA was 0.017 logMAR ± 0.030 (SD) (approximately 20/20) and the mean DCNVA, 0.009 ± 0.030 logMAR. There was statistically significant worsening of visual acuity as a function of the distance to the test (P < .01). There were no statistically significant differences in HOAs between the 2 groups (P > .01). In eyes with previous hyperopic LASIK, the diffractive IOL provided good visual quality at distance, comparable to that obtained in phakic eyes under photopic conditions, although visual performance was slightly poorer under mesopic conditions. No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 28 references indexed in Scilit:
- Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2008
- Prospective study of the Acri.LISA bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens ImplantationOphthalmology, 2007
- Prospective visual evaluation of apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens systemJournal of Cataract & Refractive Surgery, 2007
- Visual Performance of AcrySof ReSTOR Apodized Diffractive IOL: A Prospective Comparative TrialAmerican Journal of Ophthalmology, 2006
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Distance and near contrast sensitivity function after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2003