Optimisation of the Sputnik-VAD Design
- 9 July 2016
- journal article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 39 (8) , 407-414
Abstract
Purpose: Miniaturisation of VADs can offer important benefits, including less invasive implantation techniques and more versatility in patient selection. The aim of this work was to reduce the weight, size, and energy consumption of the Sputnik VAD. Methods: The second generation of the Sputnik VAD was developed with a set of changes in construction. The head pressure-flow rate (H-Q) and power consumption-flow rate curves for the Sputnik VADs were measured at different rotational speeds. Computational fluid dynamics (CFD) were used for operating condition simulation and the LVADs were compared under the simulated physiological conditions. Results: The slope of the H-Q curves for the Sputnik 1 VAD remains almost invariable over the entire range of the measured flow rate, in contrast to the curves for the Sputnik 2 VAD, which become flat in the high flow-rate region. Despite the design modification, the operating rotor speed remained invariable. The preload sensitivity of the Sputnik VAD is higher than that of the other rotary blood pumps and amounts to 0.111 ± 0.0092 L min−1 mmHg−1. The power consumption for the Sputnik 2 VAD is lower over the entire speed range, except for at 5,000 rpm. Conclusions: The pump weight was reduced from 246 to 205 g, the pump length was decreased from 82 to 66 mm, and the pump diameter was decreased from 32 to 29 mm. The total energy consumption of the pump was reduced by 15%.Keywords
This publication has 22 references indexed in Scilit:
- HYDRODYNAMIC AND HEMOLYSIS ANALYSIS ON DISTANCE AND CLEARANCE BETWEEN IMPELLER AND DIFFUSER OF AXIAL BLOOD PUMPJournal of Mechanics in Medicine and Biology, 2016
- Robust decentralised control of a hydrodynamic human circulatory system simulatorBiomedical Signal Processing and Control, 2015
- Design Concepts and Preclinical Results of a Miniaturized HeartWare Platform: The MVAD SystemInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2015
- Development of Left Ventricular Assist Devices as the Most Effective Acute Heart Failure TherapyBiomedical Engineering, 2015
- Thromboresistance Comparison of the HeartMate II Ventricular Assist Device With the Device Thrombogenicity Emulation-Optimized HeartAssist 5 VADJournal of Biomechanical Engineering, 2014
- Jarvik 2000 Pump Technology and MiniaturizationHeart Failure Clinics, 2014
- Cost of Ventricular Assist DevicesCirculation, 2013
- Orthotopic heart transplant versus left ventricular assist device: A national comparison of cost and survivalThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Sensorless Estimation of Pressure Head and Flow of a Continuous Flow Artificial Heart Based on Input Power and Rotational SpeedASAIO Journal, 2002
- Evaluation of diamond-like carbon-coated orthopaedic implantsDiamond and Related Materials, 1997