Determination of pesticides by solid phase extraction followed by gas chromatography with nitrogen–phosphorous detection in natural water and comparison with solvent drop microextraction
- 10 January 2006
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 384 (4) , 1002-1006
Abstract
The European Union specificies that drinking water can contain pesticide residues at concentrations of up to 0.1 μg/L each and 0.5 μg/L in total, and that 1–3 μg/L of pesticides can be present in surface water, but the general idea is to keep discharges, emissions and losses of priority hazardous substances close to zero for synthetic substances. Therefore, in order to monitor pesticide levels in water, analytical methods with low quantification limits are required. The method proposed here is based on solid phase extraction (SPE) followed by gas chromatography with a nitrogen–phosphorous detector (GC-NPD). During method development, six organophosphate pesticides (azinphos-ethyl, chlorfenvinphos, chlorpyriphos, ethoprophos, fenamiphos and malathion) and two organonitrogen pesticides (alachlor and deltamethrin) were considered as target analytes. Elution conditions that could influence the efficiency of the SPE were studied. The optimized methodology exhibited good linearity, with determination coefficients of better than 0.996. The analytical recovery for the target analytes ranged from 70 to 100%, while the within-day precision was 4.0–11.5 %. The data also showed that the nature of the aqueous matrice (ultrapure, surface or drinking water) had no significant effect on the recovery. The quantification limits for the analytes were found to be 0.01–0.13 μg/L (except for deltamethrin, which was 1.0 μg/L). The present methodology is easy, rapid and gives better sensitivity than solvent drop microextraction for the determination of organonitrogen and organophosphate pesticides in drinking water at levels associated with the legislation.Keywords
This publication has 18 references indexed in Scilit:
- In situ Preconcentration Method for Trace Dissolved Sulfide in Environmental Water Samples Using Solid-Phase Extraction Followed by Spectrophotometric DeterminationAnalytical Sciences, 1999
- Monitoring of pesticide residues and their metabolites in surface and underground waters of Imathia (N. Greece) by means of solid-phase extraction disks and gas chromatographyJournal of Chromatography A, 1998
- Monitoring of Insecticides and Fungicides in Water and Sediment Samples in the Brazilian EnvironmentInternational Journal of Environmental Analytical Chemistry, 1998
- Influence of solvent effects on the breakthrough volume in solid-phase extraction using porous polymer particle-loaded membranesThe Analyst, 1995
- Determination of organophosphorus and triazine pesticides in ground- and drinking water by solid-phase extraction and gas chromatography with nitrogen-phosphorus or mass spectrometric detectionJournal of Chromatography A, 1994
- Determination of Organophosphorus Insecticides in Water by C-18 Solid Phase Extraction and Quantitative TLCJournal of Liquid Chromatography, 1990
- Conversion of a conventional packed-column gas chromatograph to accommodate megabore columnsJournal of Chromatography A, 1989
- Collection of atmospheric hydrogen chloride in industrial environments by means of alumina sampling tubesAnalytica Chimica Acta, 1988
- C18 reversed-phase trace enrichment of organophosphorus pesticides and residues in waterMicrochimica Acta, 1985
- Guidelines for data acquisition and data quality evaluation in environmental chemistryAnalytical Chemistry, 1980