Characteristics of blood flow velocity in the radial artery and finger capillaries using magnetoplethysmogram and photoplethysmogram
Open Access
- 1 February 2024
- journal article
- research article
- Published by AIP Publishing in AIP Advances
- Vol. 14 (2)
Abstract
The Hall element and optical sensor, which can detect the magnetic field change caused by the minute fluctuations of the permanent magnet according to the periodic movement of the radial artery and the light absorption and reflection intensity according to the change in wrist blood flow, respectively, are used as key elements in digital healthcare devices. The pulse waves of the radial artery inside the wrist were measured and analyzed using a clip-type pulsimeter, magnetoplethysmogram (MPG). The pulse wave, which is the change in blood flow obtained by photoplethysmogram (PPG), was measured on the dorsal side of the wrist or the fingers simultaneously with MPG. The ABFV (artery blood flow velocity) is a few ten cm/s as DH (distance between MPG and PPG) divided by ΔT(a) which is the time difference between the first peaks of MPG and PPG waveforms on the dorsal side of the wrist. The PBFV (peripheral blood flow velocity) is a few mm/s as LH (hand length) divided by ΔT(p), which is the time difference between the first peak of MPG waveform and the third peak PPG waveform on the finger. For four subjects of 20s, SPWV was approximately 0.98∼1.19 m/s, ABFV in the radial artery was approximately 0.40∼0.44 m/s, and finger capillary PBFV was approximately 6.3∼8.6 cm/s. These results show reasonable values similar to the blood velocity of many blood vessels flowing through the human body.Keywords
Funding Information
- Ministry of Education (2022RIS-005)
This publication has 12 references indexed in Scilit:
- Development of Real-Time Cuffless Blood Pressure Measurement Systems with ECG Electrodes and a Microphone Using Pulse Transit Time (PTT)Sensors, 2023
- Characteristics of Spatial Pulse Wave Velocity Measured During Spinal Stimulation and Thermal Treatment with Magnetic Sensing Hall Element Pulsimeter and PhotoplethysmographyJournal of the Korean Magnetics Society, 2022
- Properties of Systolic Blood Pressure and Systolic time of Arterial Pulse Waveform According to Thermal Effect of the Upper body by Using the Shoulder Heat TherapyNew Physics: Sae Mulli, 2020
- Measurement, Analysis and Interpretation of Pressure/Flow Waves in Blood VesselsFrontiers in Physiology, 2020
- Characteristics of Blood Pressure and Pulse Waveform Using Hall Effect Sensor by Low Frequency Electrical StimulationJournal of the Korean Magnetics Society, 2019
- Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the PhotoplethysmographJournal of the Korean Magnetics Society, 2013
- Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and PhotoplethysmographySensors, 2013
- Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect DeviceJournal of Magnetics, 2011
- Measurement and Analysis of Pulse Wave Using a Clamping Pulsimeter Equipped With Hall Effect DeviceIEEE Transactions on Magnetics, 2011
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007