Anomalous diffusion measured by a twice‐refocused spin echo pulse sequence: Analysis using fractional order calculus
Open Access
- 20 April 2011
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (5) , 1177-1183
Abstract
Purpose: To theoretically develop and experimentally validate a formulism based on a fractional order calculus (FC) diffusion model to characterize anomalous diffusion in brain tissues measured with a twice‐refocused spin‐echo (TRSE) pulse sequence.Materials and Methods: The FC diffusion model is the fractional order generalization of the Bloch‐Torrey equation. Using this model, an analytical expression was derived to describe the diffusion‐induced signal attenuation in a TRSE pulse sequence. To experimentally validate this expression, a set of diffusion‐weighted (DW) images was acquired at 3 Tesla from healthy human brains using a TRSE sequence with twelve b‐values ranging from 0 to 2600 s/mm2. For comparison, DW images were also acquired using a Stejskal‐Tanner diffusion gradient in a single‐shot spin‐echo echo planar sequence. For both datasets, a Levenberg‐Marquardt fitting algorithm was used to extract three parameters: diffusion coefficient D, fractional order derivative in space β, and a spatial parameter μ (in units of μm). Using adjusted R‐squared values and standard deviations, D, β, and μ values and the goodness‐of‐fit in three specific regions of interest (ROIs) in white matter, gray matter, and cerebrospinal fluid, respectively, were evaluated for each of the two datasets. In addition, spatially resolved parametric maps were assessed qualitatively.Results: The analytical expression for the TRSE sequence, derived from the FC diffusion model, accurately characterized the diffusion‐induced signal loss in brain tissues at high b‐values. In the selected ROIs, the goodness‐of‐fit and standard deviations for the TRSE dataset were comparable with the results obtained from the Stejskal‐Tanner dataset, demonstrating the robustness of the FC model across multiple data acquisition strategies. Qualitatively, the D, β, and μ maps from the TRSE dataset exhibited fewer artifacts, reflecting the improved immunity to eddy currents.Conclusion: The diffusion‐induced signal attenuation in a TRSE pulse sequence can be described by an FC diffusion model at high b‐values. This model performs equally well for data acquired from the human brain tissues with a TRSE pulse sequence or a conventional Stejskal‐Tanner sequence. J. Magn. Reson. Imaging 2011;33:1177–1183.Keywords
This publication has 29 references indexed in Scilit:
- Studies of anomalous diffusion in the human brain using fractional order calculusMagnetic Resonance in Medicine, 2010
- Axcaliber: A method for measuring axon diameter distribution from diffusion MRIMagnetic Resonance in Medicine, 2008
- Integrated SENSE DTI with correction of susceptibility- and eddy current-induced geometric distortionsNeuroImage, 2008
- High b‐value q‐space diffusion MRS of nerves: structural information and comparison with histological evidenceNMR in Biomedicine, 2008
- From diffusion‐weighted MRI to anomalous diffusion imagingMagnetic Resonance in Medicine, 2008
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- Correction of high‐order eddy current induced geometric distortion in diffusion‐weighted echo‐planar imagesMagnetic Resonance in Medicine, 2004
- Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarityMagnetic Resonance in Medicine, 2003
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- High b‐value q‐space analyzed diffusion‐weighted MRS and MRI in neuronal tissues – a technical reviewNMR in Biomedicine, 2002