Abstract
The goal of this study is to characterize the formulation and processing factors that influence folic acid dissolution from oil- and water-soluble multivitamin with minerals tablet formulations for direct compression. The following parameters were studied: bulk filler solubility, soluble to insoluble bulk filler ratio, triturating agent (preblending carrier) solubility, disintegrant usage, compression pressure, and folic acid particle size. Folic acid particle size was determined by using light microscopy, and surface area was measured by using BET adsorption. The tablets were compressed on an instrumented Stokes B2 tablet press, and the friability, weight variation, and dissolution were measured according to USP methods, along with tablet breaking strength. In summary, we found the following factors to be critical to folic acid dissolution: bulk filler solubility (soluble fillers, such as maltose, increase folic acid dissolution); disintegrant amount (levels less than 0.4% (w/w) are ineffectual, ...

This publication has 9 references indexed in Scilit: