Primary Stability and Osseointegration of the Implant in an Iatrogenically Oversized Cavity by Bone Substitute: An Animal Study
Open Access
- 29 September 2024
- journal article
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 16 (3) , 134-139
Abstract
Background: The aim of this study was to compare the success rate of autogenous bone and combination of autogenous bone and beta-tricalcium phosphate (β-TCP) grafts in restoring the primary stability and osseointegration of dental implants after the oversized preparation of the bone cavity in animal models. Methods: Three months after extracting 3 premolars from 4 male Terrier dogs, 24 implants were inserted in cavities larger than the fixture size. Then, based on the type of graft materials around the implant fixture, they were randomly divided into the autogenous bone group (A, n=8), the autogenous bone group with β-TCP (B, n=8), and the control group with no grafts (C, n=8). After 16 weeks, the removal torque quantity (RTQ) test and Periotest® were used for osseointegration assessment. Results: According to the results of the RTQ test, group B was significantly higher than group C (P=0.022), but no statistical difference was observed between groups A and B, as well as groups A and C. Based on the results, the Periotest® value significantly differed in group B compared to groups A (P=0.049) and C (P=0.014), but there was no difference between groups A and C in this regard. Conclusions: According to the findings of the study, the combination of autogenous bone graft and TCP could improve secondary stability and osseointegration of dental implants.Keywords
This publication has 20 references indexed in Scilit:
- Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placementClinical Oral Investigations, 2020
- Can Osseointegration Be Achieved Without Primary Stability?Dental Clinics of North America, 2019
- Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibiaClinical Oral Investigations, 2016
- RETRACTED ARTICLE: Biomechanical and histological evaluation of four different titanium implant surface modifications: an experimental study in the rabbit tibiaClinical Oral Investigations, 2013
- Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analysesInternational Journal of Oral and Maxillofacial Surgery, 2013
- A new method for the evaluation of dental implant stability using an inductive sensorMedical Engineering & Physics, 2012
- Compromised Primary Implant StabilityJournal of Craniofacial Surgery, 2012
- In vivo evaluation of poorly crystalline hydroxyapatite-based biphasic calcium phosphate bone substitutes for treating dental bony defectsJournal of Dental Sciences, 2010
- Effect of Surgical Techniques on Primary Implant Stability and Peri-Implant BoneJournal of Oral and Maxillofacial Surgery, 2007
- Quantitative determination of the stability of the implant‐tissue interface using resonance frequency analysisClinical Oral Implants Research, 1996