Pressure distribution under different types of blood pressure measurement cuffs
- 16 March 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Industrial Textiles
- Vol. 47 (1) , 89-103
Abstract
The principal component of any non-invasive blood pressure measurement system is an inflatable cuff. Different types of fabrics are used for inflatable cuffs construction. In this study, sphygmomanometric blood pressure measurement using inflatable cuffs was simulated in Abaqus and validated through experimental results. The purpose of the simulation is to study the effect of variation in cuff fabric geometric and mechanical properties on pressure distribution and pressure transmission during blood pressure measurement by predicting the pressure at the interface of the blood pressure cuffs and a metal cylinder. Geometric and mechanical properties of the fabrics of four different cuff types were found experimentally. Interface pressure at the cuffs and metal cylinder surface was also found experimentally using Tekscan pressure sensing system for models validation. The results of the simulation showed that the interface pressure underneath the cuffs vary with variation in geometric and mechanical properties of their fabrics. The results of the simulation were found to be in good agreement with experimental findings. This research demonstrates that the pressure distribution under the cuffs is related to the cuffs' fabric geometric and mechanical properties. This means that variation in cuffs' fabric properties could ultimately incur variations in the blood pressure values of human subjects.Keywords
This publication has 15 references indexed in Scilit:
- Digital recording system of sphygmomanometryBlood Pressure Monitoring, 2009
- Biomechanical Engineering of Textiles and Clothing2006
- The Measurement of Interface Pressure2005
- Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society, 2004—BHS IVJournal of Human Hypertension, 2004
- A New Double Cuff Sphygmotonometer for Accurate Blood Pressure Measurement.Hypertension Research, 2001
- A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurementIEEE Transactions on Biomedical Engineering, 1996
- Accuracy of interface pressure measurement systemsJournal of Biomedical Engineering, 1993
- Pressure distribution under the ischium of normal subjectsJournal of Biomedical Engineering, 1986
- Factors Affecting Correlation Between Direct and Indirect Arterial Blood Pressure MeasurementsJournal of Clinical Engineering, 1978
- Criteria in the choice of an occluding cuff for the indirect measurement of blood pressureMedical & Biological Engineering & Computing, 1977