Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments
- 13 June 2010
- journal article
- review article
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 368 (1920) , 2725-2763
Abstract
Bone biomechanics have been extensively investigated in the past both with in vitro experiments and numerical models. In most cases either approach is chosen, without exploiting synergies. Both experiments and numerical models suffer from limitations relative to their accuracy and their respective fields of application. In vitro experiments can improve numerical models by: (i) preliminarily identifying the most relevant failure scenarios; (ii) improving the model identification with experimentally measured material properties; (iii) improving the model identification with accurately measured actual boundary conditions; and (iv) providing quantitative validation based on mechanical properties (strain, displacements) directly measured from physical specimens being tested in parallel with the modelling activity. Likewise, numerical models can improve in vitro experiments by: (i) identifying the most relevant loading configurations among a number of motor tasks that cannot be replicated in vitro ; (ii) identifying acceptable simplifications for the in vitro simulation; (iii) optimizing the use of transducers to minimize errors and provide measurements at the most relevant locations; and (iv) exploring a variety of different conditions (material properties, interface, etc.) that would require enormous experimental effort. By reporting an example of successful investigation of the femur, we show how a combination of numerical modelling and controlled experiments within the same research team can be designed to create a virtuous circle where models are used to improve experiments, experiments are used to improve models and their combination synergistically provides more detailed and more reliable results than can be achieved with either approach singularly.Keywords
This publication has 137 references indexed in Scilit:
- Structural behaviour and strain distribution of the long bones of the human lower limbsJournal of Biomechanics, 2010
- Time-lapsed assessment of microcrack initiation and propagation in murine cortical bone at submicrometer resolutionBone, 2009
- Structural Properties of a Novel Design of Composite Analogue Humeri ModelsAnnals of Biomedical Engineering, 2008
- Micromechanics-Based Conversion of CT Data into Anisotropic Elasticity Tensors, Applied to FE Simulations of a MandibleAnnals of Biomedical Engineering, 2007
- ‘Universal’ microstructural patterns in cortical and trabecular, extracellular and extravascular bone materials: Micromechanics-based prediction of anisotropic elasticityJournal of Theoretical Biology, 2007
- Validation of an automated method of three-dimensional finite element modelling of boneJournal of Biomedical Engineering, 1993
- The effect of different storage methods on the mechanical properties of trabecular boneJournal of Biomechanics, 1993
- Tensile and compressive properties of cancellous boneJournal of Biomechanics, 1991
- Automated three-dimensional finite element modelling of bone: a new methodJournal of Biomedical Engineering, 1990
- Proximal femoral surface strain gauge analysis of a new epiphyseal prosthesisJournal of Biomedical Engineering, 1989