Template-Based Insoles for the Center of Pressure Estimation in Different Foot Sizes
- 22 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (8) , 1-4
Abstract
In this letter, we present a novel simplified approach for the center of pressure estimation across different foot sizes using insole-based systems. A concept of insole templates is introduced to realize the adaptability of a single bunch of sensors across different template sizes. The proposed insole system is validated against the force platform during walking and weight shifting tasks. The experimental results show estimation accuracy with root mean square error of 1.980.57 cm during walking and 1.280.60 cm during weight shifting using UK7 insole size. Pearson correlation coefficient of 0.97.03 during walking and 0.970.05 during weight shifting was observed. The non-significant difference (p>0.05) in root mean square error and Pearson's correlation coefficient between two significantly varying foot sizes (UK7 and UK10; p<0.05) indicates the suitability of the present approach for CoP estimation in different foot sizes at low-cost during weight shifting.Keywords
This publication has 15 references indexed in Scilit:
- Polymer Optical Fiber for In-Shoe Monitoring of Ground Reaction Forces During the GaitIEEE Sensors Journal, 2018
- A Haptic Feedback System for Phase-Based Sensory Restoration in Above-Knee Prosthetic Leg UsersIEEE Transactions on Haptics, 2016
- Validity and repeatability of three in-shoe pressure measurement systemsGait & Posture, 2016
- Kinetic Gait Analysis Using a Low-Cost InsoleIEEE Transactions on Biomedical Engineering, 2013
- In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing ArrayIEEE Transactions on Information Technology in Biomedicine, 2010
- Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurementsMedical & Biological Engineering & Computing, 2008
- Use of pressure insoles to calculate the complete ground reaction forcesJournal of Biomechanics, 2004
- Do strain gauge force platforms need in situ correction?Gait & Posture, 2002
- Balance prosthesis based on micromechanical sensors using vibrotactile feedback of tiltIEEE Transactions on Biomedical Engineering, 2001
- Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurementsGait & Posture, 2000