Risk factor analysis of changes in blood flow in the A1 segment of the anterior cerebral artery after flow-diverter coverage of it
Authors:
- 5 February 2024
- journal article
- research article
- Published by Springer Nature in Neurosurgical Review
- Vol. 47 (1) , 1-6
Abstract
Few studies have explored the effect of a flow-diverter device (FD) on blood flow in the A1 segment of the anterior cerebral artery (ACA), after treatment of intracranial aneurysms in the bifurcation region of the internal carotid artery (ICA). The main objective of this article is to investigate the factors that affect A1 blood flow after FD covers the A1 artery. This is a single-center, retrospective study. Data were collected retrospectively from our center, and patients whose FDs were placed for treatment from the terminal of the ICA to the M1 segment were analyzed. A total of 42 patients were included in the study. Immediate post-procedural angiography following device placement revealed decreased blood flow in the A1 of 15 (35.7%) patients and complete occlusion of the A1 segment in 11 (26.2%) patients. During an average follow-up period of 9.8 months, the A1 segment was ultimately occluded in 25 patients (59.5%) and decreased blood flow in 4 patients (9.5%). When using FD to cover the A1 artery for the treatment of intracranial aneurysms, patients with preoperative opening of the anterior communicating artery (AcomA) are more prone to occlusion or decreased blood flow of the A1 artery, compared to patients without opening.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Flow-Diverting Stents for Intracranial Bifurcation Aneurysm TreatmentNeurosurgery, 2014
- Silk Flow-Diverter Stent for the Treatment of Intracranial Aneurysms: A Series of 58 Patients with Emphasis on Long-Term ResultsAmerican Journal of Neuroradiology, 2014
- Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment—Clinical and Anatomic ResultsAmerican Journal of Neuroradiology, 2014
- Patency of the posterior communicating artery after flow diversion treatment of internal carotid artery aneurysmsClinical Neurology and Neurosurgery, 2014
- Modifying flow in the ACA–ACoA complex: endovascular treatment option for wide-neck internal carotid artery bifurcation aneurysmsJournal of NeuroInterventional Surgery, 2014
- Flow Diverters at and Beyond the Level of the Circle of Willis for the Treatment of Intracranial AneurysmsStroke, 2012
- Validation of a patient-specific one-dimensional model of the systemic arterial treeAmerican Journal of Physiology-Heart and Circulatory Physiology, 2011
- Effect of Flow Diverter Porosity on Intraaneurysmal Blood FlowClinical Neuroradiology, 2009
- Correlation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit AneurysmsJournal of Biomechanical Engineering, 2009
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007