THE CAPTURE OF ESCHERICHIA COLI O157:H7 FOR LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR (LAPS) USING TWO DIFFERENT TYPES OF MAGNETIC BEADS1
Authors:
- 1 October 2002
- journal article
- Published by Wiley in Journal of Rapid Methods and Automation in Microbiology
- Vol. 10 (3) , 185-195
Abstract
Two types of commercially available, streptavidin‐coated magnetic beads (SAMB) were labeled with the same biotinylated anti E. coli O157 antibodies. Labeled SAMB and other necessary antibody derivatives needed for Light‐addressable Potentiometric Sensor (LAPS) detection were used to capture E. coli O157:H7 in solution. The LAPS signal intensity was then used to determine the overall bacterial capture efficiency. The static and hydrodynamic properties of the beads were then used to correlate with determined efficiencies. It was found that the capture increased as the total mass of SAMB increased. Also, greater capture with SAMB of a higher density was observed with the same bead mass. In addition, the SAMB of higher density also required less time of rocking to reach a maximum capture. These observations are in agreement with the predictions from the hydrodynamic properties of tested SAMB.Keywords
This publication has 11 references indexed in Scilit:
- Immunomagnetic separation methods for the isolation of Campylobacter jejuni from ground poultry meatsJournal of Immunological Methods, 2001
- THE USE OF STREPTAVIDIN COATED MAGNETIC BEADS FOR DETECTING PATHOGENIC BACTERIA BY LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR (LAPS)Journal of Rapid Methods and Automation in Microbiology, 2000
- Biosensors for detection of pathogenic bacteriaBiosensors and Bioelectronics, 1999
- Methodology for detection and typing of foodborne microorganismsInternational Journal of Food Microbiology, 1999
- Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7Biosensors and Bioelectronics, 1999
- DETECTION OF IMMUNOMAGNETICALLY CAPTURED, 4′,6‐DIAMIDINO‐2‐PHENYLINDOLE (DAPI)‐LABELED E. COLI O157:H7 BY FLUORESCENT MICROSCOPE IMAGING 1Journal of Rapid Methods and Automation in Microbiology, 1998
- Immunomagnetic Separation with Mediated Flow Injection Analysis Amperometric Detection of Viable Escherichia coli O157Analytical Chemistry, 1998
- Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7Journal of Immunological Methods, 1998
- Antibody-direct epifluorescent filter technique for rapid, direct enumeration of Escherichia coli O157:H7 in beefApplied and Environmental Microbiology, 1994
- Number fluctuation spectroscopy of motile microorganismsBiophysical Journal, 1975