Simple Solution for Preventing Cerebrospinal Fluid Loss and Brain Shift During Multitrack Deep Brain Stimulation Surgery in the Semisupine Position: Polyethylene Glycol Hydrogel Dural Sealant Capping
- 1 January 2013
- journal article
- research article
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 53 (1) , 1-6
Abstract
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societiesKeywords
This publication has 20 references indexed in Scilit:
- Polyethylene glycol (PEG) hydrogel dural sealant and collagen dural graft matrix in transsphenoidal pituitary surgery for prevention of postoperative cerebrospinal fluid leaksJournal of Clinical Neuroscience, 2011
- Polyethylene Glycol Hydrogel Spinal Sealant (DuraSeal Spinal Sealant) as an Adjunct to Sutured Dural Repair in the SpineSpine, 2011
- Minimizing Brain Shift during Functional Neurosurgical Procedures – A Simple Burr Hole Technique that can Decrease CSF Loss and Intracranial AirCentral European Neurosurgery, 2011
- The unsuccessful placement of a deep brain stimulation electrode due to a brain shift induced by air invasion: Case reportParkinsonism & Related Disorders, 2011
- Venous air embolism during microelectrode recording in deep brain stimulation surgery in an awake supine patientBritish Journal Of Neurosurgery, 2009
- Venous Air Embolism in Deep Brain StimulationStereotactic and Functional Neurosurgery, 2008
- Cortical and subcortical brain shift during stereotactic proceduresJournal of Neurosurgery, 2007
- Brain shift: an error factor during implantation of deep brain stimulation electrodesJournal of Neurosurgery, 2007
- Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repairJournal of Neurosurgery, 2007
- Comparison of Three Methods of Targeting the Subthalamic Nucleus for Chronic Stimulation in Parkinson's DiseaseOperative Neurosurgery, 2005