Evaluation of the original sealant with antibacterial effect for synthetic vascular grafts
Authors:
- A.A. ShadanovASA.A. Shadanov
- I.YU. ZhuravlevaIZI.YU. Zhuravleva
- L.M. SamoylovaLSL.M. Samoylova
- T.P. TimchenkoTTT.P. Timchenko
- S.V. VladimirovSVS.V. Vladimirov
- E.V. KarpovaEKE.V. Karpova
- N.E. LuchnikovNLN.E. Luchnikov
- D.A. SirotaDSD.A. Sirota
- A.G. EdemskiyAEA.G. Edemskiy
- A.V. Bogachev-ProkofievABA.V. Bogachev-Prokofiev
- A.M. ChernyavskiyACA.M. Chernyavskiy
Open Access
- 30 March 2023
- journal article
- research article
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 27 (1) , 38-46
Abstract
Background: Vascular graft infection is a severe cardiovascular complication with high mortality rates. Antibacterial vascular graft coatings are widely used and continue to be improved.Objective: To develop a sealant with antimicrobial effect for Dacron vascular grafts and experimentally test the coating properties.Methods: We used 2 types of vascular grafts: graft No. 1 (plain weave) with initial water permeability of 78.8 ± 2.7 mL/cm2/min and graft No. 2 (2/1 twill + 6/4 satin weave) with water permeability of 549.8 ± 20.7 mL/cm2/min. We developed an original gelatin impregnation technique, tested it using a scanning electron microscopy, and measured water permeability and kink radius. We evaluated the antibacterial activity of vancomycin and gelatin impregnation by the disk diffusion test using media with Staphylococcus aureus ATCC 29213 and Enterococcus faecalis ATCC 29212 and measured inhibition zones after 24-hour incubation. We used samples cut out of grafts with vancomycin-containing (experimental group) and no vancomycin-containing (control group) impregnation.Results: The gelatin coating of the samples is visualized as a thin even film and provides zero water permeability. On the negative side, it increased stiffness and the kink radius. Thanks to vancomycin added to the coating, bacterial growth significantly inhibits: the mean diameter of the growth inhibition zone for Staphylococcus aureus and Enterococcus faecalis was 15.60 ± 0.65 and 14.40 ± 0.66 mm, respectively. The grafts untreated with vancomycin showed no growth inhibition zones.Conclusion: Vascular graft treatment with gelatin impregnation and vancomycin solution is a simple measure to prevent the growth of gram-positive bacteria on vascular grafts. Received 14 November 2022. Revised 15 December 2022. Accepted 19 December 2022. Funding: The work was supported by Russian Science Foundation (project No. 22-15-20005). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: I.Yu. Zhuravleva, A.A. Shadanov, D.A. SirotaData collection and analysis: A.A. Shadanov, L.M. Samoylova, S.V. Vladimirov, T.P. Timchenko, N.E. Luchnikov, E.V. KarpovaStatistical analysis: A.A. ShadanovDrafting the article: A.A. Shadanov, L.M. Samoylova, T.P. Timchenko, A.G. EdemskiyCritical revision of the article: D.A. Sirota, I.Yu. Zhuravleva, A.V. Bogachev-Prokofiev, A.M. ChernyavskiyFinal approval of the version to be published: A.A. Shadanov, I.Yu. Zhuravleva, L.M. Samoylova, T.P. Timchenko, S.V. Vladimirov, E.V. Karpova, N.E. Luchnikov, D.A. Sirota, A.G. Edemskiy, A.V. Bogachev-Prokofiev, A.M. ChernyavskiyKeywords
This publication has 21 references indexed in Scilit:
- In vitro Evidence of Improved Antimicrobial Efficacy of Silver and Triclosan Containing Vascular Grafts Compared with Rifampicin Soaked GraftsEuropean Journal of Vascular and Endovascular Surgery, 2019
- Polyester vascular prostheses coated with a cyclodextrin polymer and activated with antibiotics: Cytotoxicity and microbiological evaluationActa Biomaterialia, 2008
- Antibiotic-eluting medical devices for various applicationsJournal of Controlled Release, 2008
- Bacterial biofilms: from the Natural environment to infectious diseasesNature Reviews Microbiology, 2004
- Impregnated Polyester Arterial Prostheses: Performance and ProspectsAnnals of Vascular Surgery, 1999
- Elution of Six Antibiotics Bonded to Polyethylene Vascular Grafts Sealed with Three ProteinsJournal of Surgical Research, 1996
- Early Inflammatory Response to Gelatin- and Collagen-Sealed Dacron ProsthesesAnnals of Vascular Surgery, 1995
- Prevention of Vascular Graft Infection by Rifampin Bonding to a Gelatin-Sealed Dacron GraftAnnals of Vascular Surgery, 1991
- Development of an Infection-Resistant Vascular ProsthesisArchives of Surgery, 1981
- A new method for producing proteic coatingsJournal of Biomedical Materials Research, 1975