Cost implications of closure of atrial septal defect
- 20 December 2001
- journal article
- pediatric intervention
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 55 (1) , 83-87
Abstract
We sought to evaluate the relative cost of surgical and device closure of atrial septal defect. Device closure for atrial septal defects is becoming an alternative to surgical closure. We examined the hospital‐generated cost data in 13 patients who underwent surgical repair and 15 patients who underwent device closure of an atrial septal defects (ASD) or patent foramen ovale (PFO) during a prospective clinical trial of the device. The cost of device closure of ASD was $7,837 less on average than surgical closure when the cost of the occlusion device was excluded (device closure cost $7,397 ± $2,822, surgical closure cost $15,234 ± $3,851; P < 0.001). When adjusted for a 5% failure rate of device closure, the cost savings was $7,076. Device closure of ASD results in substantial hospital‐related cost savings that will be an important consideration once new devices are approved for clinical use. Cathet Cardiovasc Intervent 2002;55:83–87.Keywords
This publication has 15 references indexed in Scilit:
- Cost Effectiveness of Early Discharge after Uncomplicated Acute Myocardial InfarctionNew England Journal of Medicine, 2000
- Transcatheter closure of atrial septal defect with a new flexible, self-centering device (the STARFlex Occluder)The American Journal of Cardiology, 1999
- Transcatheter closure of atrial septal defect and patent foramen ovale with the ASDOS device (a multi-institutional European trial)∗∗See Appendix for the list of participating institutions and investigators.The American Journal of Cardiology, 1998
- Comparison of hospital charges for closure of patent ductus arteriosus by surgery and by transcatheter coil occlusionThe American Journal of Cardiology, 1996
- Clinical Outcomes and Costs of Transcatheter as Compared with Surgical Closure of Patent Ductus ArteriosusNew England Journal of Medicine, 1993
- Experimental atrial septal defect closure with a new, transcatheter, self-centering device.Circulation, 1993
- Transvenous atrial septal defect occlusion by the buttoned deviceThe American Journal of Cardiology, 1990
- Double-umbrella closure of atrial defects. Initial clinical applications.Circulation, 1990
- Transcatheter closure of atrial septal defects. Experimental studies.Circulation, 1989
- Transcatheter umbrella closure of congenital heart defects.Circulation, 1987