Endoscopic Endonasal Stereoscopic Images of the Skull Base: From Creation to Automatic Evaluation
Open Access
- 11 December 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 5449-5466
Abstract
The study of neuroanatomy is an integral part of the education and training of neurosurgeons and aspiring professionals in this field, in which the use of images, videos, models, simulators, and virtual reality can fit into the pedagogy of this medical area. However, individuals who lack a solid understanding of three-dimensionality and proportion encounter challenges when interpreting two-dimensional images. Regardless of all the technology currently available, the stereoscopic images, a technique used by superimposing two images taken from the same region by moving a camera laterally, keeping the same horizontal plane and the same focal length, become valuable by presenting the viewer with the notion of depth and decreasing the learning time. However, when stereoscopic images are generated, many of them do not present the expected results, and could cause discomfort to the observer when analyzed, especially because their depth perception could be altered. In this study, a computational algorithm uses Pearson’s Correlation Coefficient, Angle between two vectors, and Oriented FAST and Rotated BRIEF (ORB) to analyze and compare the two stereo pair images. Thus, six parameters are described that best correlate the two images, classified in order using the Fisher Discriminant Ratio (FDR), and used to evaluate the quality of a set of 180 endoscopic endonasal stereo images of the skull base. This study evaluated stereo pairs to determine their suitability for accurate 3D pictures using digital image processing and classification methods. Six parameters tested were effective for class separation, with the most discriminative being the angle between column vectors in the red channel, determined by the highest FDR, and it can serve as a standalone classifier or be used in a multivariate discriminant function for automated quality assessment. This research also determines that existing quality metrics such as Unified No-Reference Quality Assessment via Monocular and the Binocular Local Visual Primitives and Top-Down JND Estimation were ineffective for this specific classification, highlighting the potential of the proposed methodology.Keywords
Funding Information
- Coordination for the Improvement of Higher Education Personnel (CAPES) for the Article Processing Charge (00x0ma614)
This publication has 47 references indexed in Scilit:
- Anatomic Considerations in Endoscopic Pituitary SurgeryOtolaryngologic Clinics of North America, 2022
- Endoscopic transnasal skull base surgery: pushing the boundariesJournal of Neuro-Oncology, 2016
- Evaluation of an online three‐dimensional interactive resource for undergraduate neuroanatomy educationAnatomical Sciences Education, 2016
- Skull Base AnatomyOtolaryngologic Clinics of North America, 2016
- A Guide to Stereoscopic 3D Displays in MedicineAcademic Radiology, 2011
- Al Rhoton as Neurosurgeon of the YearWorld Neurosurgery, 2011
- BRIEF: Binary Robust Independent Elementary Features2010
- Speeded-Up Robust Features (SURF)Computer Vision and Image Understanding, 2008
- SURF: Speeded Up Robust Features2006
- Error Detecting and Error Correcting CodesBell System Technical Journal, 1950