Sonographic Identification of Tube Thoracostomy Study (SITTS): Confirmation of Intrathoracic Placement
Authors:
- Jamie JenkinsJJJamie Jenkins
- Laleh GharahbaghianLGLaleh Gharahbaghian
- Stephanie J DonigerSDStephanie J Doniger
- Scott BradleySBScott Bradley
- Steve CrandallSCSteve Crandall
- David SpainDSDavid Spain
- Sarah R WilliamsSWSarah R Williams
Open Access
- 1 September 2012
- journal article
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 13 (4) , 305-311
Abstract
Introduction: Thoracostomy tubes (TT) are commonly placed in the management of surgical, emergency, and trauma patients and chest radiographs (CXR) and computed tomography (CT) are performed to confirm placement. Ultrasound (US) has not previously been used as a means to confirm intrathoracic placement of chest tubes. This study involves a novel application of US to demonstrate chest tubes passing through the pleural line, thus confirming intrathoracic placement. Methods: This was an observational proof-of-concept study using a convenience sample of patients with TTs at a tertiary-care university hospital. Bedside US was performed by the primary investigatorusing first the low-frequency (5–1 MHz) followed by the high-frequency (10–5 MHz) transducers, in both 2-dimensional gray-scale and M-modes in a uniform manner. The TTs were identified in transverse and longitudinal views by starting at the skin entry point and scanning to where the TT passed the pleural line, entering the intrathoracic region. All US images were reviewed by US fellowship-trained emergency physicians. CXRs and CTs were used as the standard for confirmation ofTT placement. Results: Seventeen patients with a total of 21 TTs were enrolled. TTs were visualized entering the intrathoracic space in 100% of cases. They were subjectively best visualized with the high-frequency (10–5 MHz) linear transducer. Sixteen TTs were evaluated using M-mode. TTs produced a distinct pattern on M-mode. Conclusion: Bedside US can visualize the TT and its entrance into the thoracic cavity and it can distinguish it from the pleural line by a characteristic M-mode pattern. This is best visualized with the high-frequency (10–5 MHz) linear transducer. [West J Emerg Med. 2012;13(4):305–311.]Keywords
This publication has 33 references indexed in Scilit:
- An initial description of a sonographic sign that verifies intrathoracic chest tube placementThe American Journal of Emergency Medicine, 2010
- Residual Hemothorax after Chest Tube Placement Correlates with Increased Risk of Empyema Following Traumatic InjuryCanadian Respiratory Journal, 2008
- Ultrasound to detect haemothorax after chest injuryEmergency Medicine Journal, 2007
- Complications of intercostal catheter insertion using EMST techniques for chest traumaAnz Journal of Surgery, 2004
- ED screening to identify abdominal aortic aneurysms in asymptomatic geriatric patientsThe American Journal of Emergency Medicine, 2003
- Performance and interpretation of focused right upper quadrant ultrasound by emergency physiciansThe Journal of Emergency Medicine, 2001
- The comet-tail artifact: an ultrasound sign ruling out pneumothoraxIntensive Care Medicine, 1999
- Bedside sonographic-guided versus blind nasoenteric feeding tube placement in critically ill patientsCritical Care Medicine, 1996
- Ultrasound in emergency medicineThe American Journal of Emergency Medicine, 1996
- Complications after emergency tube thoracostomy: assessment with CT.Radiology, 1995