Abstract
Commercial antimicrobial susceptibility testing (AST) systems were introduced into clinical microbiology laboratories during the 1980s and have been used in the majority of laboratories since the 1990s. Manual and semiautomated broth microdilution systems are utilized for small volumes of susceptibility testing, while larger laboratories often choose an automated broth microdilution system. The AST systems include data management software that may be interfaced with a laboratory information system (LIS) and offer various levels of expert system and epidemiological analyses. This chapter focuses primarily on commercial susceptibility testing systems currently available in the United States. It discusses advantages and disadvantages of automated systems. Reports of AST performance for detecting problematic resistance phenotypes are also discussed. Expert systems to assist in the critical review of AST results are available for all commercial susceptibility systems currently marketed in the United States. Most expert systems use a rules-based approach focusing on AST results for one drug at a time without considering results for other agents tested simultaneously. Factors to consider when selecting an AST system include cost, performance, work flow, data management capabilities, and manufacturer technical support. Future advances in the development of AST systems may increase their clinical impact with the incorporation of molecular techniques that dramatically shorten the time required for results.Keywords
This publication has 92 references indexed in Scilit:
- BD Phoenix and Vitek 2 Detection of mecA -Mediated Resistance in Staphylococcus aureus with CefoxitinJournal of Clinical Microbiology, 2009
- Performance of MicroScan WalkAway and Vitek 2 for Detection of Oxacillin Resistance in a Set of Methicillin-Resistant Staphylococcus aureus Isolates with Diverse Genetic BackgroundsJournal of Clinical Microbiology, 2009
- Accuracy of Commercial and Reference Susceptibility Testing Methods for Detecting Vancomycin-Intermediate Staphylococcus aureusJournal of Clinical Microbiology, 2009
- Detecting imipenem resistance in Acinetobacter baumannii by automated systems (BD Phoenix, Microscan WalkAway, Vitek 2); high error rates with Microscan WalkAwayBMC Infectious Diseases, 2009
- Evaluation of New Vitek 2 Card and Disk Diffusion Method for Determining Susceptibility of Staphylococcus aureus to OxacillinJournal of Clinical Microbiology, 2008
- Performance of Vitek 2 in Antimicrobial Susceptibility Testing of Pseudomonas aeruginosa Isolates with Different Mechanisms of β-Lactam ResistanceJournal of Clinical Microbiology, 2008
- Multicenter Evaluation of the BD Phoenix Automated Microbiology System for Antimicrobial Susceptibility Testing of Streptococcus SpeciesJournal of Clinical Microbiology, 2007
- Accuracy of Six Antimicrobial Susceptibility Methods for Testing Linezolid against Staphylococci and EnterococciJournal of Clinical Microbiology, 2007
- Drug susceptibility testing of clinical isolates of streptococci and enterococci by the Phoenix automated microbiology systemBMC Microbiology, 2007
- Evaluation of the BD Phoenix Automated Microbiology System for Identification and Antimicrobial Susceptibility Testing of Staphylococci and EnterococciJournal of Clinical Microbiology, 2006