Measurement of the intraocular pressure with the “transpalpebral tonometer” TGDc-01 in comparison with applanation tonometry
Authors:
- 22 December 2004
- journal article
- clinical trial
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (6) , 563-569
Abstract
An irregular corneal surface compromises IOP measurement by Goldmann applanation tonometry. In such cases accurate measurement without corneal contact would be desirable. The new eyelid tonometer TGDc-01 measures IOP without corneal contact through the eyelid. The aim of the study was to evaluate the accuracy of the eyelid tonometer compared with Goldmann applanation tonometry (cornea thickness-corrected values) in subjects without corneal alterations. IOP was measured in 199 eyes of 103 subjects without corneal alterations by means of two different methods. Measurements with the transpalpebral tonometer TGDc-01 and the Goldmann applanation tonometer were performed within 5 min in random order. The mean difference between lid tonometry and Goldmann applanation tonometry was 0.71 mmHg, SD ±2.467 mmHg. In the reliability analysis the intraclass correlation coefficient was 0.8620. Compared with Goldmann applanation tonometry 66.4% of the IOP readings measured by lid tonometry were in an interval of ±2 mmHg, 81.0% in an interval of ±3 mmHg. The maximum of deviation was −6 mmHg and +6 mmHg, respectively. The Bland and Altman plots are shown. Lid tonometry correlates sufficiently with Goldmann applanation tonometry, but in more than 10% of the measurements the IOP readings differed by more than 3 mmHg. The eyelid tonometer may be helpful as a screening tool when Goldmann applanation tonometry is not applicable.Keywords
This publication has 15 references indexed in Scilit:
- The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deteriorationAmerican Journal of Ophthalmology, 2000
- Impressions- und Applanationstonometrie bei pathologischen Hornh uten im Vergleich mit der intraokularen NadeldruckmessungDer Ophthalmologe, 2000
- The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucomaAmerican Journal of Ophthalmology, 1998
- Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressuresAmerican Journal of Ophthalmology, 1998
- Retinal Hemodynamics Using Scanning Laser Ophthalmoscopy and Hemorheology in Chronic Open-angle GlaucomaOphthalmology, 1993
- Pressure compliance of the optic nerve head in low tension glaucoma.British Journal of Ophthalmology, 1987
- Blood and plasma viscosity measurements in patients with glaucoma.British Journal of Ophthalmology, 1985
- Retinal Autoregulation in Open-angle GlaucomaOphthalmology, 1984
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975
- Über ApplanationstonometrieOphthalmologica, 1957