Salvage of C2 Pedicle and Pars Screws Using the Intralaminar Technique
Authors:
- Ronald A. LehmanRLRonald A. Lehman
- Anton E. DmitrievADAnton E. Dmitriev
- Melvin D. HelgesonMHMelvin D. Helgeson
- Rick C. SassoRSRick C. Sasso
- Timothy R. KukloTKTimothy R. Kuklo
- K Daniel RiewKRK Daniel Riew
- 1 April 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (9) , 960-965
Abstract
Human cadaveric biomechanical analysis. The purpose of this study is to evaluate the ability of using 1 of the remaining 2 methods of instrumenting C2, should the initial method fail. Although 3 different methods of C2 fixation (pedicle, pars, and laminar screws) are possible, occasionally an attempt at screw insertion fails. In such cases, the surgeon needs a viable alternative to salvage/obtain fixation to obviate the need to instrument an additional motion segment. Eleven fresh-frozen cadaveric specimens (Occ-C4) were DEXA scanned for bone mineral density. On the left side, pedicle screws were first inserted, then pulled out. Then, “salvage” pars screws were inserted, then pulled-out, followed by laminar screws. On the right, a similar sequence was repeated, except that a pars screw was followed by a pedicle screw, then a laminar screw. All screws were placed by experienced cervical spine surgeons. Insertional torque (IT) was measured in Newton-meters (Nm). Tensile loading to failure was performed “in-line”with the screw axis at a rate of 0.25 mm/s using a MTS 858 MiniBionix II System with data recorded as peak pull-out strength (POS) in newtons “N”. Pedicle screws generated statistically greater IT and POS than other techniques as the initial fixation type (P < 0.0001). Similar trends were observed with transpedicular fixation as a salvage procedure (P > 0.05). Laminar screws yielded consistently higher POS values than pars fixation when applied in a salvage scenario (POS range: LS = 146–707 N; PrS = 8–548 N); however, high standard deviation precluded statistical significance (P > 0.05). Significant predictive relationship was established between IT and POS for all screws using Pearson correlation coefficient and bivariate linear regression analysis (r = 0.75 and r2 = 0.511, respectively; P < 0.01). Our results suggest that pedicle screws provide the strongest fixation for both initial and salvage applications. If they should fail, lamina screws appear to provide stronger and more reproducible fixation than pars screws.Keywords
This publication has 15 references indexed in Scilit:
- Translaminar rigid screw fixation of the axisJournal of Neurosurgery: Spine, 2005
- Constructs Incorporating Intralaminar C2 Screws Provide Rigid Stability for Atlantoaxial FixationSpine, 2005
- Posterior C2 Fixation Using Bilateral, Crossing C2 Laminar ScrewsJournal of Spinal Disorders, 2004
- Posterior C1–C2 Fusion With Polyaxial Screw and Rod FixationSpine, 2001
- Modified Gallie Technique Versus Transarticular Screw Fixation in C1-C2 FusionClinical Orthopaedics and Related Research, 1999
- Anatomic Study for Ideal and Safe Posterior C1-C2 Transarticular Screw FixationSpine, 1998
- Variation of the Groove in the Axis Vertebra for the Vertebral ArteryThe Journal of Bone and Joint Surgery. British volume, 1997
- Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation techniqueJournal of Neurosurgery, 1997
- The anatomical suitability of the C1–2 complex for transarticular screw fixationJournal of Neurosurgery, 1996
- Fractures and dislocations of the cervical spineThe American Journal of Surgery, 1939