Sensing and detection in Medtronic implantable cardioverter defibrillators
Authors:
- 8 September 2016
- journal article
- review article
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 27 (3) , 193-212
Abstract
Ensuring sensing and detection of ventricular tachycardia (VT) and ventricular fibrillation (VF) was a prerequisite for the clinical trials that established the survival benefit of implantable cardioverter defibrillators (ICDs). However, for decades, a high incidence of unnecessary shocks limited patients’ and physicians’ acceptance of ICD therapy. Oversensing, misclassification of supraventricular tachycardia (SVT) as VT, and self-terminating VT accounted for the vast majority of unnecessary shocks. Medtronic ICDs utilize sensitive baseline settings with minimal blanking periods to ensure accurate sensing of VF, VT, and SVT electrograms. Programmable algorithms reject oversensing caused by far-field R waves, T waves, and non-physiologic signals caused by lead failure. A robust hierarchy of SVT-VT discriminators minimize misclassification of SVT as VT. These features, combined with evidence-based programming, have reduced the 1‑year inappropriate shock rate to 1.5 % for dual-/triple-chamber ICDs and to 2.5 % for single-chamber ICDs.Keywords
This publication has 34 references indexed in Scilit:
- Diaphragmatic Myopotential Oversensing Caused by Change in Implantable Cardioverter Defibrillator Sensing Bandpass FilterPacing and Clinical Electrophysiology, 2016
- Sinus rhythm R-wave amplitude as a predictor of ventricular fibrillation undersensing in patients with implantable cardioverter-defibrillatorHeart Rhythm, 2015
- ICD Follow‐Up and Troubleshooting2014
- Undersensing by an ICD Due to Alternans of the Ventricular ElectrogramAnnals of Noninvasive Electrocardiology, 2012
- ICD-unresponsive ventricular arrhythmiasHeart Rhythm, 2009
- Improving SVT Discrimination in Single‐Chamber ICDs: A New Electrogram Morphology‐Based AlgorithmJournal of Cardiovascular Electrophysiology, 2006
- Undersensing of VF in a Patient With Optimal R Wave Sensing During Sinus RhythmPacing and Clinical Electrophysiology, 2004
- Safety Margins for Sensing and Detection: Programming Tradeoffs1996
- Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillatorJACC, 1994
- Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillatorJACC, 1994