Validation of a 0‐/2‐Hour High‐Sensitivity Cardiac Troponin Algorithm for Suspected Acute Coronary Syndrome in the Emergency Department
Authors:
- Dustin G MarkDMDustin G Mark
- Keane K LeeKLKeane K Lee
- Dana R SaxDSDana R Sax
- Dustin W BallardDBDustin W Ballard
- David R VinsonDVDavid R Vinson
- Kaiser Permanente CREST Network InvestigatorsKIKaiser Permanente CREST Network Investigators
Open Access
- 7 October 2025
- journal article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (19) , e043756
Abstract
Background: We implemented a hs‐cTnI (high‐sensitivity cardiac troponin I)‐based algorithm for emergency department (ED) evaluation of possible non‐ST–segment‐elevation acute coronary syndrome within an integrated health system (Kaiser Permanente Northern California). Methods: Retrospective study of adult (18+ years) ED encounters for chest pain/discomfort with hs‐cTnI testing (Access hsTnI, Beckman) at 21 medical centers between January 1, 2023 and June 30, 2024, excluding ST–segment‐elevation myocardial infarction. The primary outcome was 30‐day myocardial infarction or death. Sensitivity, specificity, negative predictive value, positive predictive value, and likelihood ratios were reported, with subgroup analyses by age, sex, coronary artery disease, chronic kidney disease, and ED disposition. Results: There were 104 025 encounters in the final cohort (median age 59 years, 45% male, 18% coronary artery disease, and 13% chronic kidney disease). The primary outcome occurred in 5.5% encounters. Rule‐out criteria were present in 70% of encounters (sensitivity, 95.4% [95% CI, 94.8%–96.0%]; negative predictive value, 99.7% [95% CI, 99.6%–99.7%]; likelihood ratio, −0.05) and 7% of encounters met rule‐in criteria (specificity, 96.7% [95% CI, 96.6–96.8%]; positive predictive value, 60.2% [95% CI, 59.3%–61.1%]; likelihood ratio, +24.4). In subgroup analyses, rule‐out criteria negative predictive value was below 99% in stage 4+ chronic kidney disease (96.1% [95% CI, 94.6%–97.6%]) and ischemic coronary artery disease (98.6% [95% CI 98.3–98.9%]), though not among those selected for ED discharge (98.4% [95% CI, 96.7%–99.2%] and 99.1% [95% CI, 98.8%–99.4%], respectively). Conclusions: The Kaiser Permanente Northern California non‐ST–elevation acute coronary syndrome evaluation algorithm demonstrated excellent overall performance. Negative predictive value was modestly diminished in ischemic coronary artery disease or advanced chronic kidney disease, but risk was largely mitigated by ED discharge disposition decisions.Keywords
This publication has 40 references indexed in Scilit:
- Diagnostic Performance of High-Sensitivity Cardiac Troponin I in a Multicenter U.S. Emergency Department CohortJACC: Advances, 2023
- Performance of the European Society of Cardiology 0/1-Hour Algorithm With High-Sensitivity Cardiac Troponin T Among Patients With Known Coronary Artery DiseaseJAMA Cardiology, 2023
- 2022 ACC Expert Consensus Decision Pathway on the Evaluation and Disposition of Acute Chest Pain in the Emergency DepartmentJACC, 2022
- Use of High-Sensitivity Cardiac Troponin in Patients With Kidney ImpairmentJAMA Internal Medicine, 2021
- Downstream Cascades of Care Following High-Sensitivity Troponin Test ImplementationJACC, 2021
- High-Sensitivity Cardiac Troponin Concentrations at Presentation in Patients With ST-Segment Elevation Myocardial InfarctionJAMA Cardiology, 2020
- Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial InfarctionJACC, 2019
- Clinical Policy: Critical Issues in the Evaluation and Management of Emergency Department Patients With Suspected Non–ST-Elevation Acute Coronary SyndromesAnnals of Emergency Medicine, 2018
- Prospective Validation of the 0/1-h Algorithm for Early Diagnosis of Myocardial InfarctionJACC, 2018
- A GEE approach to estimating sensitivity and specificity and coverage properties of the confidence intervalsStatistics in Medicine, 2001