A Finite Element Analysis and Circuit Modelling Methodology for Studying Electrical Impedance Myography of Human Limbs
Open Access
- 23 June 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (1) , 244-255
Abstract
Objective: Electrical impedance myography (EIM) measures bioimpedance over muscles. This paper proposes a circuit-based modelling methodology originated from finite element analysis (FEA), to emulate tissues and effects from anthropometric variations, and electrode placements, on EIM measurements. The proposed methodology is demonstrated on the upper arms and lower legs. Methods: FEA evaluates impedance spectra (Z-parameters), sensitivity, and volume impedance density for variations of subcutaneous fat thickness (t $_{f}$ ), muscle thickness (t $_{m}$ ), and inter-electrode distance (IED), on limb models over 1Hz-1 MHz frequency range. The limbs’ models are based on simplified anatomical data and dielectric properties from published sources. Contributions of tissues to the total impedance are computed from impedance sensitivity and density. FEA Z-parameters are imported into a circuit design environment, and used to develop a three Cole dispersion circuit-based model. FEA and circuit model simulation results are compared with measurements on ten human subjects. Results: Muscle contributions are maximized at 31.25 kHz and 62.5 kHz for the upper arm and lower leg, respectively, at 4 cm IED. The circuit model emulates variations in t $_{f}$ and t $_{m}$ , and simulates up to 89 times faster than FEA. The circuit model matches subjects measurements with RMS errors $\mathbf {< \;}36.43\boldsymbol{\Omega }$ and $\mathbf {< \;}17.28\mathbf {^{\circ }}$ , while FEA does with $\mathbf {< \;}36.59\boldsymbol{\Omega }$ and $\mathbf {< \;}4.36\mathbf {^{\circ }}$ . Conclusions: We demonstrate that FEA is able to estimate the optimal frequencies and electrode placements, and circuit-based modelling can accurately emulate the limbs’ bioimpedance. Significance: The proposed methodology facilitates studying the impact of biophysical principles on EIM, enabling the development of future EIM acquisition systems.Keywords
Funding Information
- Strategiska Stiftelsen für Forskning Project
- Implanterbart bioimpedans spectrometer (ITM17-0079)
This publication has 19 references indexed in Scilit:
- A Batteryless Sensor ASIC for Implantable Bio-Impedance ApplicationsIEEE Transactions on Biomedical Circuits and Systems, 2015
- Optimizing Electrode Configuration for Electrical Impedance Measurements of Muscle via the Finite Element MethodIEEE Transactions on Biomedical Engineering, 2013
- Assessment of Alterations in the Electrical Impedance of Muscle After Experimental Nerve Injury via Finite-Element AnalysisIEEE Transactions on Biomedical Engineering, 2011
- Reference values for 50‐kHZ electrical impedance myographyMuscle & Nerve, 2008
- Assessing neuromuscular disease with multifrequency electrical impedance myographyMuscle & Nerve, 2006
- Cole Electrical Impedance Model—A Critique and an AlternativeIEEE Transactions on Biomedical Engineering, 2004
- Epidermal Thickness at Different Body Sites: Relationship to Age, Gender, Pigmentation, Blood Content, Skin Type and Smoking HabitsActa Dermato-Venereologica, 2003
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Tissue impedance: a historical overviewPhysiological Measurement, 1995