Non-Stress Test Changes During Acupuncture Plus Moxibustion on BL67 Point in Breech Presentation
Authors:
- Isabella NeriINIsabella Neri
- Marta FazzioMFMarta Fazzio
- Simona MenghiniSMSimona Menghini
- Annibale VolpeAVAnnibale Volpe
- 1 May 2002
- journal article
- research article
- Published by Springer Nature in Journal of the Society for Gynecologic Investigation
- Vol. 9 (3) , 158-162
Abstract
Objectives:We assessed fetal heart variability and activity using a computerized non-stress test (NST) during acupuncture plus moxibustion on the BL67 point. For comparison, the same changes were assessed during placebo acupuncture (minimal acupuncture) in the same subjects. Methods:Twelve pregnant women in the 33rd week of gestation, carrying singletons in the breech presentation were enrolled in the study. In a single-blind design, each woman received a first session of minimal acupuncture followed 1-2 days later by true acupuncture. During the sessions, women were monitored using computerized non-stress testing starting 20 minutes before the stimuli and continuing for 20 minutes after treatment. Results:During true acupuncture a significant reduction in fetal baseline heart rate, and more accelerations and movement were observed. During minimal acupuncture, there were no significant changes in these variables. No signs of fetal distress or changes in short- or long-term variability were noted, and there were no uterine contractions. Conclusion:In our study population, acute application of acupuncture plus moxibustion did not cause fetal distress as assessed by either fetal heart rate decelerations or changes in either short- to long-term variability. Considering that the modifications in fetal movement and heart rate occurred in true but not during minimal acupuncture, we could consider that such changes are related to the effect of the acupuncture stimulation. The mechanisms leading to the cephalic version remain to be clearly established.Keywords
This publication has 11 references indexed in Scilit:
- Temporal changes in fetal cardiovascular, behavioural, metabolic and endocrine responses to maternally administered dexamethasone in the late gestation fetal sheepBJOG: An International Journal of Obstetrics & Gynaecology, 1999
- Moxibustion for Correction of Breech PresentationJAMA, 1998
- The credibility of placebo controls in acupuncture studiesComplementary Therapies in Medicine, 1998
- Cardiovascular and Endocrine Effects of Acupuncture in Hypertensive PatientsClinical and Experimental Hypertension, 1997
- The advantages of computerized fetal heart rate analysisJournal of Perinatal Medicine, 1991
- Computer‐assisted analysis of fetal behavioural statesPrenatal Diagnosis, 1988
- Effect of naloxone on fetal behavior near termAmerican Journal of Obstetrics and Gynecology, 1987
- modifications of ultradian and orcadian rhythms of fetal heart rate after fetal‐maternal adrenal gland suppression: A double blind studyPrenatal Diagnosis, 1986
- Primary Headaches: Reduced Circulating β-Lipotropin and β-Endorphin Levels with Impaired Reactivity to AcupunctureCephalalgia, 1981
- Increased Cerebrospinal Fluid Levels of Endorphins after Electro‐AcupunctureActa Physiologica Scandinavica, 1977