Signal Quality Indices Evaluation for Optimized Radar-Based Blood Pressure Monitoring
Authors:
- 5 December 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 209-211
Abstract
This paper proposes a signal quality indices determination for blood pressure estimation based on pulse waveform detected by a SIL radar. 6 selected features are extracted from the pre-processed signal. After that, the proposed signal quality estimation analysis is conducted to assess whether reliable blood pressure can be obtained from the collected signal. Unlike traditional signal quality algorithms, this algorithm does not evaluate the signal as a whole and discards it if the results are poor. Each pulse is evaluated separately, and just the low-quality pulses are removed. The advantage of this method is that it reduces sampling time while improving blood pressure prediction accuracy. The algorithms are validated on manually labelled data. Compared with the reference blood pressure obtained by a sphygmomanometer, the model’s mean absolute error (MAE) performance can be decreased by 10% to 40%, proving that this method can effectively measure blood pressure using a single radar in a non-contact state.Keywords
This publication has 11 references indexed in Scilit:
- A Compact 1.0–12.5-GHz LNA MMIC With 1.5-dB NF Based on Multiple Resistive Feedback in 0.15-μm GaAs pHEMT TechnologyIEEE Transactions on Circuits and Systems I: Regular Papers, 2023
- Cuffless blood pressure estimation using chaotic features of photoplethysmograms and parallel convolutional neural networkComputer Methods and Programs in Biomedicine, 2022
- Design and Analysis of a Cascode Distributed LNA With Gain and Noise Improvement in 0.15-μm GaAs pHEMT TechnologyIEEE Transactions on Circuits and Systems II: Express Briefs, 2022
- Radar-based blood pressure estimation using multiple features2022
- A medical radar system for non-contact vital sign monitoring and clinical performance evaluation in hospitalized older patientsBiomedical Signal Processing and Control, 2022
- Validation of noncontact cardiorespiratory monitoring using impulse-radio ultra-wideband radar against nocturnal polysomnographySleep and Breathing, 2019
- Automatic Signal Quality Index Determination of Radar-Recorded Heart Sound Signals Using Ensemble ClassificationIEEE Transactions on Biomedical Engineering, 2019
- Signal quality measure for pulsatile physiological signals using morphological features: Applications in reliability measure for pulse oximetryInformatics in Medicine Unlocked, 2019
- Self-injection-locked radar: An advance in continuous-wave technology for emerging radar systems2013
- A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare MonitoringIEEE Transactions on Microwave Theory and Techniques, 2013