Time Course Changes of Synthetic Relaxation Time During Neoadjuvant Chemotherapy in Breast Cancer: The Optimal Parameter for Treatment Response Evaluation
Authors:
- 9 January 2023
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (4) , 1290-1302
Abstract
Background: Synthetic MRI (syMRI) has enabled quantification of multiple relaxation parameters (T1/T2 relaxation time [T1/T2], proton density [PD]), and their longitudinal change during neoadjuvant chemotherapy (NAC) promises to be valuable parameters for treatment response evaluation in breast cancer. Purpose: To investigate the time course changes of syMRI parameters during NAC and evaluate their value as predictors for pathological complete response (pCR) in breast cancer. Study Type: Retrospective, longitudinal. Population: A total of 129 women (median age, 50 years; range, 28–69 years) with locally advanced breast cancer who underwent NAC; all performed multiple conventional breast MRI examinations with added syMRI during NAC. Field Strength/Sequence: A 3.0 T, T1 ‐weighted dynamic contrast enhanced and syMRI acquired by a multiple‐dynamic, multiple‐echo sequence. Assessment: Breast MRI was set at four time‐points: baseline, after one cycle, after three or four cycles of NAC and preoperation. SyMRI parameters and tumor diameters were measured and their changes from baseline were calculated. All parameters were compared between pCR and non‐pCR. Interaction between syMRI parameters and clinicopathological features was analyzed. Statistical Tests: Mann–Whitney U tests, random effects model of repeated measurement, receiver operating characteristic (ROC) analysis, interaction analysis. Results: Median synthetic T1/T2/PD and tumor diameter generally decreased throughout NAC. Absolute T1 at early‐NAC, T1, and PD at mid‐NAC were significantly lower in the pCR group. After early‐NAC, the T1 change was significantly higher in the pCR (median ± IQR, 18.17 ± 11.33) than the non‐pCR group (median ± IQR, 10.90 ± 10.03), with the highest area under the ROC curves (AUC) of 0.769 (95% CI, 0.684–0.838). Interaction analysis showed that histological grade III patients had higher odds ratio (OR) (OR = 1.206) compared to grade II patients (OR = 1.067). Data Conclusion: Synthetic T1 changes after one cycle of NAC maybe useful for early evaluating NAC response in breast cancer during whole treatment cycles. However, its discriminative ability is significantly affected by histological grade. Evidence Level: 4 Technical Efficacy: Stage 2.Keywords
Funding Information
- National Natural Science Foundation of China (81971695)
This publication has 36 references indexed in Scilit:
- DCE‐MRI analysis methods for predicting the response of breast cancer to neoadjuvant chemotherapy: Pilot study findingsMagnetic Resonance in Medicine, 2013
- Recommendations from an International Consensus Conference on the Current Status and Future of Neoadjuvant Systemic Therapy in Primary Breast CancerAnnals of Surgical Oncology, 2011
- American Society of Clinical Oncology/College of American Pathologists Guideline Recommendations for Immunohistochemical Testing of Estrogen and Progesterone Receptors in Breast CancerJournal of Clinical Oncology, 2010
- Quantified Tumor T1 Is a Generic Early-Response Imaging Biomarker for Chemotherapy Reflecting Cell ViabilityClinical Cancer Research, 2010
- New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)European Journal of Cancer, 2009
- Lesion T2 relaxation times and volumes predict the response of malignant breast lesions to neoadjuvant chemotherapyMagnetic Resonance Imaging, 2008
- Novel method for rapid, simultaneous T1, T*2, and proton density quantificationMagnetic Resonance in Medicine, 2007
- Determining the longitudinal relaxation time (T1) of blood at 3.0 TeslaMagnetic Resonance in Medicine, 2004
- T1ρ of protein solutions at very low fields: Dependence on molecular weight, concentration, and structureMagnetic Resonance in Medicine, 1997
- Quantitative magnetic resonance imaging in cervical carcinoma: a report on 30 casesBritish Journal of Radiology, 1991