Dual gating myocardial perfusion SPECT denoising using a conditional generative adversarial network
Authors:
- 17 May 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 49 (8) , 5093-5106
Abstract
Purpose: Dual respiratory–cardiac gating reduces respiratory and cardiac motion blur in myocardial perfusion single‐photon emission computed tomography (MP‐SPECT). However, image noise is increased as detected counts are reduced in each dual gate (DG). We aim to develop a denoising method for dual gating MP‐SPECT images using a 3D conditional generative adversarial network (cGAN).Methods: Twenty extended cardiac‐torso phantoms with various 99mTc‐sestamibi distributions, defect characteristics, and body and organ sizes were used in the simulation, modeling six respiratory and eight cardiac gates (CGs), that is, 48 DGs for ordered subset expectation maximization reconstruction. Twenty clinical 99mTc‐sestamibi SPECT/CT datasets were re‐binned into 7 respiratory gates and 8 CGs, that is, 56 DGs for maximum likelihood expectation maximization reconstruction. We evaluated the use of (i) phantoms’ own datasets (patient‐specific denoising [PD]) or other phantoms’ datasets (cross‐patient denoising) for training; (ii) the CG or the static (non‐gated [NG]) data as the training references for cGAN; and (iii) cGAN as compared to conventional 3D post‐reconstruction filtering, cardiac gating methods, and convolutional neural network. Normalized mean squared error, noise as assessed by normalized standard deviation, spatial blurring measured as the full‐width‐at‐half‐maximum of left ventricular wall, ejection fraction, joint correlation histogram, and defect size were analyzed as metrics of image quality.Results: Training using patients’ own dataset is superior to conventional training based on other patients’ data. Using CG image as training reference provides a better trade‐off in terms of noise and image blur as compared to the use of NG. cGAN‐CG‐PD provides superior performance as compared to other denoising methods for all physical and diagnostic indices evaluated in both simulation and clinical studies.Conclusions: cGAN denoising is promising for dual gating MP‐SPECT based on the metrics mentioned earlier.Keywords
Funding Information
- National Natural Science Foundation of China
This publication has 27 references indexed in Scilit:
- Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: Effect on left ventricular functional parametersJournal of Nuclear Cardiology, 2017
- The Importance of Skip Connections in Biomedical Image Segmentation2016
- Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer studyPhysics in Medicine & Biology, 2015
- Design of a digital phantom population for myocardial perfusion SPECT imaging researchPhysics in Medicine & Biology, 2014
- Filtering in SPECT Image ReconstructionInternational Journal of Biomedical Imaging, 2011
- Single photon-emission computed tomographyJournal of Nuclear Cardiology, 2010
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Evaluating image denoising methods in myocardial perfusion single photon emission computed tomography (SPECT) imagingMeasurement Science and Technology, 2009
- Investigation of Respiratory Gating in Quantitative Myocardial SPECTIEEE Transactions on Nuclear Science, 2009
- Myocardial perfusion scintigraphy: the evidenceEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003