A Direct Peak DC-link Boost Voltage Control Strategy in Z-Source Inverter
Authors:
- 1 February 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition
- No. 10482334,p. 648-653
Abstract
A PID controller for direct peak dc-link boost voltage in Z-source inverter has been introduced. With this technique a high-performance inverter output voltage can be achieved with an excellent transient performance which enhances the rejection of disturbance, including the input voltage ripple and load current variation, and have good ride-through for voltage-sags. The peak dc-link voltage direct sensing & scaling method, and modified modulation strategy have been described, which simplify the controller design, improve the transient response and decrease the voltage stress across the switches. The proposed technique was verified on a 10-kW prototype. The experimental results meet the simulation and analysis results very well.Keywords
This publication has 4 references indexed in Scilit:
- A PID Control Strategy for DC-link Boost Voltage in Z-source InverterAPEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition, 2007
- Modeling and design of multi-loop closed loop controller for Z-source inverter for distributed generation2006
- Transient modeling and analysis of pulse-width modulated z-source inverter2005
- Z-source inverterIEEE Transactions on Industry Applications, 2003