Hill‐based musculoskeletal model for a fracture reduction robot
- 10 March 2021
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (3) , 1-14
Abstract
Background: The introduction of fracture reduction robot can solve the problem of large reduction forces during fracture reduction surgeries and the need to collect multiple medical images. However, because its safety has not been certified, there are few academic achievements on this type of robot. To calculate the safety factor during its operation, a musculoskeletal model needs to be established to study the constraints of muscles on the robot. The existing academic achievements of musculoskeletal modelling are mainly for application such as rehabilitation treatment and collision in car accidents.Methods: A musculoskeletal model applied to the fracture reduction robot is proposed in this paper. First, by comparing the characteristics of mainstream muscle models and combining the biological characteristics of the anesthetised muscles, the Hill model was selected as the muscle model for this study. Second, based on the motion composition of six spatial degrees of freedom, five basic fractural malposition situations are proposed. Then, a 170‐cm tall male musculoskeletal model was built in Opensim. Based on this model, the muscle force curves of the above malposition situations are calculated. Finally, a similar musculoskeletal model was established in Adams, and the accuracy of its muscle force data was tested. The study is approved by the ethics committee of the Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, Beijing, China.Results: The muscle force curve of Opensim and Adams model under situations of five basic malposition are compared. Most of the correlation coefficients are in the range of 0.98–0.99. The overall correlation coefficient is greater than 0.95.Conclusions: The simulation results prove that this model can be used for the safety assessment of the fracture reduction robots. This model will be served as an environmental constraint to study the control of fracture reduction robot.Keywords
Funding Information
- National Natural Science Foundation of China (52005120)
This publication has 14 references indexed in Scilit:
- Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human GaitIEEE Transactions on Biomedical Engineering, 2016
- Lumbar load estimation using a musculoskeletal model in consideration of vertebral body displacement: Lumbar load simulation under static conditions2015
- A visual servo-based teleoperation robot system for closed diaphyseal fracture reductionProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2015
- Advancing computer-assisted orthopaedic surgery using a hexapod device for closed diaphyseal fracture reductionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2014
- Comparison of stress on knee cartilage during kneeling and standing using finite element modelsMedical Engineering & Physics, 2014
- A Removable Hybrid Robot System for Long Bone Fracture ReductionBio-Medical Materials and Engineering, 2014
- Projective invariant biplanar registration of a compact modular orthopaedic robotBio-Medical Materials and Engineering, 2014
- Improving the efficacy of electrical stimulation-induced leg cycle ergometry: an analysis based on a dynamic musculoskeletal modelIEEE Transactions on Rehabilitation Engineering, 1993
- Muscle Structure and Theories of ContractionProgress in Biophysics and Biophysical Chemistry, 1957
- The heat of shortening and the dynamic constants of muscleProceedings of the Royal Society of London. B. Biological Sciences, 1938